Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Confirmation of 20–mm (50–W) and 125–mm (500–W) Test Flames for Small-Scale Burning Tests on Plastic Materials
Automaticky preložený názov:
Štandardná prax pre potvrdenie 20 & ndash; mm (50 & ndash, W) a 125 & ndash; mm (500 & ndash, W) Test Flames u malých spaľovacích skúšok na plastické hmoty
NORMA vydaná dňa 1.5.2014
Označenie normy: ASTM D5207-14
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.5.2014
Kód tovaru: NS-30281
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Plastické hmoty obecně
Výrobky z pryže a plastických hmot obecně
Keywords:
confirmation, flammability, laboratory burner, small-scale burning tests, test flames, ICS Number Code 83.080.01 (Plastics in general),83.140.01 (Rubber and plastic products in general)
Significance and Use | ||||||||||||||||||
5.1 The flame height and color (indicative of air-to-gas ratio) for a test flame have traditionally been specified in the individual test method. The energy content of the flame has also been addressed by reference to a specific supply gas. It has been determined that the supply-gas back pressure and flow rate can be varied without affecting the height and color of the flame. However, the energy content of the flame is affected. This practice provides the back pressure and flow rate of the supply gas for a 20-mm (50–W) and a 125-mm (500–W) test flame, and a procedure for confirming the heat-evolution profile of the test flame. 5.2 Information is provided for test flames using methane, propane, or butane. Using this information, these supply gases can be used interchangeably with a standardized burner to produce essentially the same test flame. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice covers the confirmation of test flames for small-scale burning tests on plastic materials using the laboratory burner described in Specification D5025. Back pressures and flow rates for methane, propane, and butane supply gases are given for specific test flames. This practice describes a procedure to confirm the heat evolution of the test flame. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions. 1.4 Fire testing is inherently
hazardous. Adequate safeguards for personnel and property shall be
employed in conducting these tests.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
1.7.2010
Historická
1.8.2012
Historická
1.7.2010
Historická
1.4.2010
Historická
1.4.2013
Historická
1.11.2013
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-02 (Počet položiek: 2 210 347)
© Copyright 2024 NORMSERVIS s.r.o.