Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for X-Ray Determination of Retained Austenite in Steel with Near Random Crystallographic Orientation (Withdrawn 2022)
Automaticky preložený názov:
Štandardné praktiky pre X-Ray Stanovenie zvyškového austenitu v oceli s Near Random kryštalografie orientácia
NORMA vydaná dňa 15.2.2013
Označenie normy: ASTM E975-13
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.2.2013
Kód tovaru: NS-48672
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
austenite, crystallographic orientation, ferrite, martensite, retained austenite, X-ray diffraction, ICS Number Code 77.080.20 (Steels)
Significance and Use | |||||||||||
2.1 Significance—Retained austenite with a near random crystallographic orientation is found in the microstructure of heat-treated low-alloy, high-strength steels that have medium (0.40 weight %) or higher carbon contents. Although the presence of retained austenite may not be evident in the microstructure, and may not affect the bulk mechanical properties such as hardness of the steel, the transformation of retained austenite to martensite during service can affect the performance of the steel. 2.2 Use—The measurement of retained austenite can be included in low-alloy steel development programs to determine its effect on mechanical properties. Retained austenite can be measured on a companion sample or test section that is included in a heat-treated lot of steel as part of a quality control practice. The measurement of retained austenite in steels from service can be included in studies of material performance. |
|||||||||||
1. Scope | |||||||||||
1.1 This practice covers the determination of retained austenite phase in steel using integrated intensities (area under peak above background) of X-ray diffraction peaks using chromium Kα or molybdenum Kα X-radiation. 1.2 The method applies to carbon and alloy steels with near random crystallographic orientations of both ferrite and austenite phases. 1.3 This practice is valid for retained austenite contents from 1 % by volume and above. 1.4 If possible, X-ray diffraction peak interference from other crystalline phases such as carbides should be eliminated from the ferrite and austenite peak intensities. 1.5 Substantial alloy contents in steel cause some change in peak intensities which have not been considered in this method. Application of this method to steels with total alloy contents exceeding 15 weight % should be done with care. If necessary, the users can calculate the theoretical correction factors to account for changes in volume of the unit cells for austenite and ferrite resulting from variations in chemical composition. 1.6 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. hkl |
Sinθ/λ |
θ |
f |
Δf′ |
Δf" |
/F/2 |
LP |
P |
TB |
N2 |
R |
(α iron, body-centered cubic, unit-cell dimension ao = 2.8664Å): |
|||||||||||
110 |
0.24669 |
34.41 |
18.474 |
−1.6 |
0.9 |
1142.2 |
4.290 |
12 |
0.9577 |
0.001803B |
101.5C |
200 |
0.34887 |
53.06 |
15.218 |
−1.6 |
0.9 |
745.0 |
2.805 |
6 |
0.9172 |
0.001803B |
20.73C |
211 |
0.42728 |
78.20 |
13.133 |
−1.6 |
0.8 |
534.6 |
9.388 |
24 |
0.8784 |
0.001803B |
190.8C |
(γ iron, face-centered cubic, unit-cell dimension a o = 3.60Å): |
|||||||||||
111 |
0.24056 |
33.44 |
18.687 |
−1.6 |
0.9 |
4684.4 |
4.554 |
8 |
0.9597 |
0.0004594B |
75.24C |
200 |
0.27778 |
39.52 |
17.422 |
−1.6 |
0.9 |
4018.3 |
3.317 |
6 |
0.9467 |
0.0004594B |
34.78C |
220 |
0.39284 |
64.15 |
14.004 |
−1.6 |
0.8 |
2472.0 |
3.920 |
12 |
0.8962 |
0.0004594B |
47.88C |
Historická
15.11.2012
Historická
1.6.2014
Historická
1.5.2010
Historická
1.5.2014
Historická
1.5.2014
Historická
15.5.2013
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-05-08 (Počet položiek: 2 198 869)
© Copyright 2025 NORMSERVIS s.r.o.