Standard Test Method for Cold Filter Plugging Point of Diesel and Heating Fuels
Automaticky preložený názov:
Štandardná skúšobná metóda pre Bod zákalu nafty a palív
NORMA vydaná dňa 1.8.2010
Označenie normy: ASTM D6371-05(2010)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.8.2010
Kód tovaru: NS-34857
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
automated cold filter plugging point, cold filter plugging point (CFPP), diesel, domestic heating fuels, filterability, manual cold filter plugging point, Automated cold filter plugging point, CFPP (cold filter plugging point), Cold filter plugging point, Diesel engine fuel oils, Domestic heating fuels, Heating fuel oils, Manual cold filter plugging point, ICS Number Code 75.160.20 (Liquid fuels)
Significance and Use | ||||||||||||||||||||
The CFPP of a fuel is suitable for estimating the lowest temperature at which a fuel will give trouble-free flow in certain fuel systems. In the case of diesel fuel used in European light duty trucks, the results are usually close to the temperature of failure in service except when the fuel system contains, for example, a paper filter installed in a location exposed to the weather or if the filter plugging temperature is more than 12°C below the cloud point value in accordance with Test Method D2500, D5771, D5772, or D5773. Domestic heating installations are usually less critical and often operate satisfactorily at temperatures somewhat lower than those indicated by the test results. The difference in results obtained from the sample as received and after heat treatment at 45°C for 30 min can be used to investigate complaints of unsatisfactory performance under low temperature conditions. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method covers the determination of the cold filter plugging point (CFPP) temperature of diesel and domestic heating fuels using either manual or automated apparatus. Note 1—This test method is technically equivalent to test methods IP 309 and EN 116. 1.2 The manual apparatus and automated apparatus are both suitable for referee purposes. 1.3 This test method is applicable to distillate fuels, including those containing a flow-improving or other additive, intended for use in diesel engines and domestic heating installations. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 WARNINGMercury has been designated by many regulatory agencies as a hazardous material that can cause central nervous system, kidney and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Material Safety Data Sheet (MSDS) for details and EPA’s websitehttp://www.epa.gov/mercury/faq.htmfor additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements, see Section 7. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Historická
1.8.2014
Historická
15.4.2012
Historická
15.6.2013
Historická
1.10.2010
Historická
1.11.2012
Historická
15.6.2013
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-22 (Počet položiek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.