Standard Practice for Static Calibration of Electronic Transducer-Based Pressure Measurement Systems for Geotechnical Purposes (Withdrawn 2018)
Automaticky preložený názov:
Štandardná prax pre statické kalibráciu elektronických Prevodník-Based tlaku meracie systémy pre geotechnických účely
NORMA vydaná dňa 15.2.2009
Označenie normy: ASTM D5720-95(2009)
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.2.2009
Kód tovaru: NS-32278
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
calibration, electronic equipment, instrumentation, manometer, pressure gauge, pressure-measuring instrument, pressure standard, pressure transducer, sensor, Calibration--soil/rock analysis instrumentation, Electronic devices/instruments/equipment, Field testing--geosynthetics, Geotechnical testing, Instrumental measurement--environmental applications, Manometer, Pressure-measuring instrumentation, Pressure testing--soil, Pressure transducers
Significance and Use | ||
Electronic transducer-based pressure measurement systems must be subjected to static calibration under room conditions to ensure reliable conversion from system output to pressure during use in laboratory or in field applications. Transducer-based pressure measurement systems should be calibrated before initial use and at least quarterly thereafter and after any change in the electronic or mechanical configuration of a system. Transducer-based pressure measurement systems should also be recalibrated if a component is dropped; overloaded; if ambient test conditions change significantly; or for any other significant changes in a system. Static calibration is not appropriate for transducerbased systems used under operating environmental conditions involving vibration, shock, or acceleration. |
||
1. Scope | ||
1.1 This practice covers the procedure for static calibration of electronic transducer-based systems used to measure fluid pressures in laboratory or in field applications associated with geotechnical testing. 1.2 This practice is used to determine the accuracy of electronic transducer-based pressure measurement systems over the full pressure range of the system or over a specified operating pressure range within the full pressure range. 1.3 This practice may also be used to determine a relationship between pressure transducer system output and applied pressure for use in converting from one value to the other (calibration curve). This relationship for electronic pressure transducer systems is usually linear and may be reduced to the form of a calibration factor or a linear calibration equation. 1.4 The values stated in SI units are to be regarded as the standard. The inch-pound units in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 7. |
||
2. Referenced Documents | ||
|
Historická
1.4.2012
Historická
1.5.2013
Historická
1.12.2013
Historická
1.4.2011
Historická
1.11.2011
Historická
1.11.2008
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.