Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
Automaticky preložený názov:
Štandard Specification pre poly (vinylchloridu) (PVC) Kanalizačné potrubie a armatúry
NORMA vydaná dňa 1.2.2011
Označenie normy: ASTM D2729-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.2.2011
Kód tovaru: NS-21330
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
drain pipe, fittings, perforated pipe, pipe, poly(vinyl chloride), PVC, Thermoplastic pipe/tube/fittings--specifications, Poly(vinyl chloride)(PVC) fittings--specifications, Poly(vinyl chloride)(PVC) pipe--specifications, Septic tank systems--specifications, Sewer pipe (thermoplastic)--specifications, ICS Number Code 23.040.20 (Plastic pipes), 23.040.45 (Plastic fittings)
Significance and Use | ||||||||||||||||||||||||
The pipe and fittings in this specification are designed and have the physical, chemical, and other properties for sewer and drainage applications outside the building. The pipe is not intended for use as public or municipal collector sewers. The following lists the typical applications for the sewer and drain pipe: Building sewers and underground drainsstandard, Storm drainagestandard and perforated, House connections to septic tanksstandard, Leaching system piping for septic tank effluentsstandard and perforated, Footing drains (foundation drains)standard and perforated, Industrial waste disposalstandard and perforated, and Land drainagestandard and perforated. |
||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, chemical resistance, and joint tightness of poly(vinyl chloride) (PVC) sewer and drain pipe and fittings. Perforated pipe is also covered; the joint tightness test is not applicable for perforated pipe. A form of marking to indicate compliance with this specification is also included. 1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification. 1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 The following precautionary caveat pertains only to the test methods portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||