Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practices for Preparation and Preliminary Testing of Water-Formed Deposits
Automaticky preložený názov:
Štandardné postupy pre prípravu a predbežného testovanie Water-tvoril Vklady
NORMA vydaná dňa 1.1.2013
Označenie normy: ASTM D2331-08(2013)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.1.2013
Kód tovaru: NS-20049
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
atomic absorption, crystallographic examination, deposits, microscopy, sample preparation, scale, spectrographic analysis , x-ray diffraction, x-ray fluorescence, ICS Number Code 13.060.60 (Examination of water for physical properties)
Significance and Use | ||||||||||||||||||||||||||
4.1 Deposits in piping from aqueous process streams serve as an indicator of fouling, corrosion or scaling. Rapid techniques of analysis are useful in identifying the nature of the deposit so that the reason for deposition can be ascertained. 4.2 Possible treatment schemes can be devised to prevent deposition from reoccurring. 4.3 Deposits formed from or by water in all its phases may be further classified as scale, sludge, corrosion products or biological deposits. The overall composition of a deposit or some part of a deposit may be determined by chemical or spectrographic analysis; the constituents actually present as chemical substances may be identified by microscope or X-ray. |
||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||
1.1 These practices provide directions for the preparation of the sample for analysis, the preliminary examination of the sample, and methods for dissolving the analytical sample or selectively separating constituents of concern. 1.2 The general practices given here can be applied to analysis of samples from a variety of surfaces that are subject to water-formed deposits. However, the investigator must resort to individual experience and judgement in applying these procedures to specific problems. 1.3 The practices include the following:
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Practice for Examination of
Water-Formed Deposits by Chemical Microscopy Standard Specification for Reagent
Water Standard Terminology Relating to Water
(Includes all amendments and changes 2/14/2024). Standard Specification for Woven Wire
Test Sieve Cloth and Test Sieves Standard Practices for Identification of
Crystalline Compounds in Water-Formed Deposits By X-Ray
Diffraction Standard Practices for Sampling
Water-Formed Deposits Standard Practice for Filamentous Iron
Bacteria in Water and Water-Formed Deposits Standard Practice for Reporting Results
of Examination and Analysis of Water-Formed Deposits Standard Practice for Analysis of
Water-Formed Deposits by Wavelength-Dispersive X-Ray
Fluorescence |
Historická
1.2.2011
Historická
1.12.2010
Historická
1.1.2014
Historická
15.7.2009
Historická
1.2.2009
Historická
1.2.2014
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-22 (Počet položiek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.