Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Automaticky preložený názov:
Štandardné skúšobné metódy pre Trvanie Nastavenie hydraulického cementu Vicat Needle
NORMA vydaná dňa 1.12.2013
Označenie normy: ASTM C191-13
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2013
Kód tovaru: NS-12475
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
automatic vicat, hydraulic-cement paste, time of setting, vicat, vicat needle, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
Significance and Use | ||||||||||||||||||||||||
5.1 This test method provides a means of determining compliance with a specification limit for Vicat time of setting. Refer to the appropriate specification for the cement to determine if this test method is used for specification compliance. 5.2 Time of setting measured by this method will not necessarily provide the same results as the time of setting of hydraulic cement paste measured by other methods, or the time of setting of mortar or concrete. |
||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||
1.1 These test methods determine the time of setting of hydraulic cement by means of the Vicat needle. Two test methods are given; Method A is the Reference Test Method using the manually operated standard Vicat apparatus, while Method B permits the use of an automatic Vicat machine that has, in accordance with the qualification requirements of this method, demonstrated acceptable performance. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Warning: Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2 1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.
|
|
Standard Specification for Reference Masses and Devices for Determining Mass and Volume for Use in Physical Testing of Hydraulic Cements
|
|
Standard Performance Specification for Hydraulic Cement
|
|
Standard Specification for Reagent Water
|
|
Standard Practice for Sampling and the Amount of Testing of Hydraulic Cement
|
|
Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste
|
|
Standard Test Method for Autoclave Expansion of Hydraulic Cement
|
|
Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
|
|
Standard Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency
|
|
Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes
|
|
Standard Specification for Blended Hydraulic Cements
|
|
Standard Specification for Portland Cement
|
|
Standard Terminology Relating to Hydraulic and Other Inorganic Cements (Includes all amendments and changes 8/28/2020). |