Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Uranium and Plutonium Concentrations and Isotopic Abundances by Thermal Ionization Mass Spectrometry
Automaticky preložený názov:
Štandardná skúšobná metóda pre urán a plutónium spájanie a Izotopické hojnosti tepelnou ionizáciou hmotnostnej spektrometrie
NORMA vydaná dňa 1.6.2012
Označenie normy: ASTM C1625-12
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2012
Kód tovaru: NS-12066
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
thermal ionization mass spectrometry, uranium, plutonium, isotope ratio, atom percent, mass percent, isotope dilution mass spectrometry, ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
Significance and Use | ||||||||||||||||||||||||||||||
Uranium and plutonium oxides can be used as a nuclear-reactor fuel in the form of pellets. In order to be suitable for use as a nuclear fuel the starting material must meet certain specifications, such as found in Specifications C757, C833, C753, C776, C1008, or as specified by the purchaser. The uranium and/or plutonium concentration and isotopic abundances are measured by mass spectrometry following this test method. The separated heavy element fractions placed on mass spectrometric filaments must be very pure. The quantity required depends upon the sensitivity of the instrument detection system. If an electron multiplier detector is to be used, only a few nanograms are required. If a Faraday cup is used, a few micrograms are needed. Chemical purity of the sample becomes more important as the sample size decreases, because ion emission of the sample is suppressed by impurities. |
||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||
1.1 This test method covers the determination of the concentration and isotopic composition of uranium and plutonium in solutions. The purified uranium or plutonium from samples ranging from nuclear materials to environmental or bioassay matrices is loaded onto a mass spectrometric filament. The isotopic ratio is determined by thermal ionization mass spectrometry, the concentration is determined by isotope dilution. 1.2 The values stated in SI units are to be regarded as the standard. Values in parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Historická
1.6.2009
Historická
1.6.2012
Historická
1.1.2012
Historická
1.1.2013
Historická
1.1.2013
Historická
1.7.2014
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-03 (Počet položiek: 2 209 203)
© Copyright 2024 NORMSERVIS s.r.o.