IEEE Guide for the Application of Electric Machines in Zone 2 and Class I, Division 2 Hazardous (Classified) Locations
NORMA vydaná dňa 15.10.2021
Označenie normy: IEEE 1349-2021
Dátum vydania normy: 15.10.2021
Kód tovaru: NS-1038876
Počet strán: 211
Približná hmotnosť: 664 g (1.46 libier)
Krajina: Medzinárodná technická norma
Kategória: Technické normy IEEE
Revision Standard - Active.
Three-phase and single-phase ac synchronous and induction electric machines in ratings 0.18 kW (1/4 hp) and larger are covered in this guide. Primary emphasis is on the use of open or non-explosion proof or non-flame proof enclosed machines in Zone 2 and Class I, Division 2 locations as covered in the NEC(R) (NFPA 70-2020) and CE Code(R) (CSA C22.1-2021) as applicable. Surface temperature test methods and sine wave and non-sine wave applications are covered. Precautions against excessive surface temperatures and sparking are included. To help mitigate hot surface temperatures and sparking, this document provides guidance for selecting, operating, and maintaining machines in Zone 2 and Class I, Division 2 locations. This guide does not cover ac wound rotor machines and dc electric machines. Machines installed in locations other than Zone 2 and Class I, Division 2 as covered in NFPA 70-2020 or CSA C22.1-2021 are not covered in this guide. This document is not a specification and is not intended to be used as a specification for purchasing electric machines. The voltage breaks in this document are 1000 V and less, and over 1000 V. (Additional documents for this standard can be downloaded at />
ISBN: 978-1-5044-7722-2, 978-1-5044-7723-9
Number of Pages: 211
Product Code: STD24806, STDPD24806
Keywords: adjustable speed drive; auto ignition temperature; Class I, Division 2; classified locations; electric machine; enclosure sparking; generator; hazardous locations; IEEE 1349; induction motor; label test; motor; motor enclosure; motor temperature; multisection motor; paint test; rotor; rotor sparking; rotor temperature; space heater test; synchronous motor; T Code; temperature code, Zone 2
Category: Petroleum and Chemical
IEEE Guide for the Application of Electric Machines in Zone 2 and Class I, Division 2 Hazardous (Classified) Locations - Corrigendum 1