Norma IEC 61267-ed.3.0-CMV 31.3.2026 náhľad

IEC 61267-ed.3.0-CMV

Medical diagnostic X-ray equipment - Radiation conditions for use in the determination of characteristics



NORMA vydaná dňa 31.3.2026


Jazyk
Prevedenie
DostupnosťSKLADOM
Cena547.00 bez DPH
547.00

Informácie o norme:

Označenie normy: IEC 61267-ed.3.0-CMV
Dátum vydania normy: 31.3.2026
Kód tovaru: NS-1265894
Počet strán: 89
Približná hmotnosť: 298 g (0.66 libier)
Krajina: Medzinárodná technická norma
Kategória: Technické normy IEC

Kategórie - podobné normy:

Radiografická zařízení

Anotácia textu normy IEC 61267-ed.3.0-CMV :

IEC 61267:2026 CMV contains both the official standard and its commented version. The commented version provides you with a quick and easy way to compare all the changes between IEC 61267:2025 edition 3.0 and the previous IEC 61267:2005 edition 2.0. Furthermore, comments from IEC SC 62C experts are provided to explain the reasons of the most relevant changes, or to clarify any part of the content. IEC 61267:2025 applies to test procedures which, for the determination of characteristics of systems or components of medical diagnostic X-ray equipment, require well-defined X-ray radiation conditions. This document deals with methods for generating X-ray radiation conditions which can be used under test conditions typically found in test laboratories or in manufacturing facilities for the determination of characteristics of medical diagnostic X-ray equipment. IEC 61267:2025 cancels and replaces the second edition published 2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) removing former Annex C “Measurement of the practical peak voltage”; b) inserting informative “Tabulated values for the squared signal-to-noise ratio per air kerma (SNR2in)” and normative “Additional X-ray radiation conditions as used in mammography and determination of the corresponding nominal aluminium half-value layers”; c) revision of X-ray radiation conditions; d) new method for verification of X-ray radiation conditions; e) change of term definitions.

Doporučujeme:




Cookies Cookies

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.

Súhlas môžete odmietnuť tu.

Tu máte možnosť prispôsobiť si nastavenia súborov cookies v súlade s vlastnými preferenciami.

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov.