ČSN P CEN/TS 17693-1 (721020)

Zemní práce - Zkoušky upravených zemin - Část 1: Zkouška pH pro stanovení obsahu vápna pro stabilizaci zemin (Bod stmelení vápnem LFP, Optimální obsah vápna pro úpravu LMO) (Norma k přímému použití jako ČSN).



NORMA vydaná dňa 1.4.2022


Jazyk
Prevedenie
DostupnosťSKLADOM
Cena8.80 bez DPH
8.80

Informácie o norme:

Označenie normy: ČSN P CEN/TS 17693-1
Rozlišovací znak: 721020
Katalógové číslo: 514176
Dátum vydania normy: 1.4.2022
Kód tovaru: NS-1052606
Počet strán: 20
Približná hmotnosť: 60 g (0.13 libier)
Krajina: Česká technická norma
Kategória: Technické normy ČSN

Anotácia textu normy ČSN P CEN/TS 17693-1 (721020):

This document specifies requirements for design, calculation and installation of factory made thermal insulated bonded single and twin pipe systems for buried hot water networks for continuous operation with treated water at various temperatures up to 120 °C and occasionally peak temperatures up to 140 °C for maximum 300 h/a, and maximum internal pressure 2,5 MPa. Flexible pipe systems according to the EN 15632 series are not under the scope of this standard. The standard EN 13941, Design and installation of thermal insulated bonded single and twin pipe systems for directly buried hot water networks consists of two parts: a) EN 13941 1: Design; b) EN 13941 2: Installation. The requirements in this part, EN 13941 2, form a unity with those of EN 13941 1. The principles of the standard may be applied to thermal insulated pipe systems with pressures higher than 2,5 MPa, provided that special attention is paid to the effects of this higher pressure. Adjacent pipes, not buried, but belonging to the network (e.g. pipes in ducts, valve chambers, road crossings above ground etc.) may be designed and installed according to this standard. This standard presupposes the use of treated water, which by softening, demineralization, de-aeration, adding of chemicals, or otherwise has been treated to effectively prevent internal corrosion and deposits in the pipes. NOTE - For further information on water qualities to be used in district heating pipe systems, see bibliographic entry [8]. This document is not applicable for such units as: a) pumps; b) heat exchangers; c) boilers, tanks; d) systems behind domestic substations

Doporučujeme:




Cookies Cookies

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.

Súhlas môžete odmietnuť tu.

Tu máte možnosť prispôsobiť si nastavenia súborov cookies v súlade s vlastnými preferenciami.

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov.