ČSN EN ISO 5167-5 (257710)

Měření průtoku tekutin pomocí snímačů diferenčního tlaku vložených do zcela zaplněného potrubí kruhového průřezu - Část 5: Kuželové průtokoměry (Norma k přímému použití jako ČSN).



NORMA vydaná dňa 1.4.2023


Jazyk
Prevedenie
DostupnosťSKLADOM
Cena13.50 bez DPH
13.50

Informácie o norme:

Označenie normy: ČSN EN ISO 5167-5
Rozlišovací znak: 257710
Katalógové číslo: 516580
Dátum vydania normy: 1.4.2023
Kód tovaru: NS-1137405
Počet strán: 28
Približná hmotnosť: 84 g (0.19 libier)
Krajina: Česká technická norma
Kategória: Technické normy ČSN

Kategórie - podobné normy:

Průtok v uzavřených potrubích

Anotácia textu normy ČSN EN ISO 5167-5 (257710):

This document specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter might be too high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1. This document is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, ß, and Reynolds number, Re. This document is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 × 104 or greater than 1,2 x 107. A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the nose of the cone upstream. The design of cone meter defined in this document has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar. Alternative designs of cone meters are available; however, at the time of writing, there is insufficient data to fully characterize these devices, and therefore, these meters shall be calibrated in accordance with Clause 7

Odporúčame:

EviZak - všetky zákony vrátane ich evidencie na jednom mieste

Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !

Chcete vedieť viac informácii ? Pozrite sa na túto stránku.




Cookies Cookies

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.

Súhlas môžete odmietnuť tu.

Tu máte možnosť prispôsobiť si nastavenia súborov cookies v súlade s vlastnými preferenciami.

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov.