ČSN EN ISO 14146 (404315)

Radiační ochrana - Kritéria a pracovní limity pro periodické hodnocení dozimetrických služeb (Norma k přímému použití jako ČSN).



NORMA vydaná dňa 1.9.2021


Jazyk
Prevedenie
DostupnosťSKLADOM
Cena13.50 bez DPH
13.50

Informácie o norme:

Označenie normy: ČSN EN ISO 14146
Rozlišovací znak: 404315
Katalógové číslo: 512580
Dátum vydania normy: 1.9.2021
Kód tovaru: NS-1034819
Počet strán: 24
Približná hmotnosť: 72 g (0.16 libier)
Krajina: Česká technická norma
Kategória: Technické normy ČSN

Kategórie - podobné normy:

Ochrana proti radiaci

Anotácia textu normy ČSN EN ISO 14146 (404315):

quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type-tested) dosimetry system and the training and experience of the staff, together with the calibration procedures and quality assurance programmes. This document specifies the criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and/or area dosemeters. An area dosemeter can be a workplace dosemeter or an environmental dosemeter. The performance evaluation can be carried out as a part of the approval procedure for a dosimetry system or as an independent check to verify that a dosimetry service fulfils specified national or international type test performance requirements under representative exposure conditions that are expected or mimic workplace fields from the radiological activities being monitored. This document applies to personal and area dosemeters for the assessment of external photon radiation with a (fluence weighted) mean energy between 8 keV and 10 MeV, beta radiation with a (fluence weighted) mean energy between 60 keV and 1,2 MeV, and neutron radiation with a (fluence weighted) mean energy between 25,3 meV (i.e. thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV) and 200 MeV. It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month). Active dosemeters (for dose measurement) may also be treated according to this document. Then, they should be treated as if they were passive (i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization)

Odporúčame:

Aktualizácia zákonov

Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.




Cookies Cookies

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.

Súhlas môžete odmietnuť tu.

Tu máte možnosť prispôsobiť si nastavenia súborov cookies v súlade s vlastnými preferenciami.

Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov.