Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Determination of Soluble Residual Contaminants in Materials by Ultrasonic Extraction (Includes all amendments And changes 7/13/2023).
NORMA vydaná dňa 1.5.2016
Označenie normy: ASTM G136-03(2016)e1
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.5.2016
Kód tovaru: NS-682906
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Zkušební podmínky a postupy všeobecně
Fyzikálně chemické analytické metody
Keywords:
contaminant, contamination, extraction, nonvolatile residue, oxygen systems, total carbon (TC), ultrasonic extraction ,, ICS Number Code 19.020 (Test conditions and procedures in general),71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||
5.1 This practice is suitable for the determination of extractable substances that may be found in materials used in systems or components requiring a high level of cleanliness, such as oxygen systems. Soft goods, such as seals and valve seats, may be tested as received. Gloves and wipes, or samples thereof, to be used in cleaning operations may be evaluated prior to use to ensure that the proposed extracting agent does not extract or deposit chemicals, or both, on the surface to be cleaned. 5.2 Wipes or other cleaning equipment may be tested after use to determine the amount of contaminant removed from a surface. Note 1: The amount of material extracted may be dependent upon
the frequency and power density of the ultrasonic unit.
5.3 The extraction efficiency has been shown to vary with the frequency and power density of the ultrasonic unit. The unit, therefore, must be carefully evaluated to optimize the extraction conditions. |
||||||||
1. Scope | ||||||||
1.1 This practice may be used to extract nonvolatile and semivolatile residues from materials such as new and used gloves, new and used wipes, component soft goods, and so forth. When used with proposed cleaning materials (wipes, gloves, and so forth), this practice may be used to determine the potential of the proposed solvent or other fluids to extract contaminants (plasticizers, residual detergents, brighteners, and so forth.) and deposit them on the surface being cleaned. 1.2 This practice is not suitable for the evaluation of particulate contamination. 1.3 The values stated in SI units are to be regarded standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Posledná aktualizácia: 2024-12-21 (Počet položiek: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.