Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Specification for Polycarbonate Resin for Medical Applications
NORMA vydaná dňa 1.12.2018
Označenie normy: ASTM F997-18
Dátum vydania normy: 1.12.2018
Kód tovaru: NS-936520
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Ostatní normy týkající se laboratorního lékařství
Termoplasty
This specification covers the general, physical property, and biocompatibility requirements, and the associated test methods for establishing a reasonable level of confidence concerning the performance of unfilled thermoplastic polycarbonate resin for use in the manufacture of medical devices or the components thereof.
Keywords:
plastics (thermoplastic), plastic surgical devices/applications, polycarbonate (PC) plastics, polymers-surgical applications, resins-polycarbonate, seals,, ICS Number Code 11.100.99 (Other standards related to laboratory medicine), 83.080.20 (Thermoplastic materials)
1. Scope | ||||||||||||||||||||||||||||||||||||
1.1 This specification covers polycarbonate resin and provides requirements and associated test methods for this thermoplastic when it is to be used in the manufacture of medical devices or components of medical devices. 1.2 As with any material, some characteristics may be altered by the processing techniques (such as molding, extrusion, machining, assembly, sterilization, and so forth) required for the production of a specific part or device. Therefore, properties of fabricated forms of this resin should be evaluated using those test methods that are appropriate to assure safety and efficacy. 1.3 The properties included in this specification are those applicable for polycarbonate only. The biocompatibility of plastic compounds made up of polycarbonate resin containing colorants, fillers, processing aids, or other additives, as well as polymer blends which contain polycarbonate, should not be assumed. The biocompatibility of these modified polycarbonates must be established by testing the final (end-use) compositions using the appropriate methods of evaluation. In addition, the biocompatibility of the material depends to a large degree on the nature of the end-use application. It is, therefore, necessary to specify a set of biocompatibility test methods for each new and distinct application. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||
|
Posledná aktualizácia: 2024-12-22 (Počet položiek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.