Standard Specification for Polyethylene (PE) Plastic Pipe (DR-PR) Based on Outside Diameter (Includes all amendments And changes 6/24/2013).
Automaticky preložený názov:
Štandardné špecifikácie pre polyetylénu ( PE ) plastových rúr ( DR - PR ) , na základe Vonkajší priemer
NORMA vydaná dňa 1.11.2012
Označenie normy: ASTM F714-12a
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2012
Kód tovaru: NS-56216
Počet strán: 12
Približná hmotnosť: 36 g (0.08 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
industrial pipe, non-pressure pipe, plastic pipe, polyethylene pipe, pressure pipe, sewer pipe, water pipe, ICS Number Code 23.040.20 (Plastic pipes)
1. Scope | ||||||||||||||||||||||||||
1.1 This specification covers polyethylene (PE) pipe made in dimensions based on outside diameters of 90 mm (3.500 in.) and larger. 1.2 Three standard outside diameter sizing systems are detailed: one known as the ISO metric system, one known as the IPS system, and the other known as the DIPS system. See 1.3 The piping is intended for new construction and insertion renewal of old piping systems used for the transport of water, municipal sewage, domestic sewage, industrial process liquids, effluents, slurries, etc., in both pressure and nonpressure systems. 1.4 All pipes produced under this
specification are pressure-rated. See Appendix X5 for information on pressure
rating.
1.5 This specification includes
criteria for choice of raw material, together with performance
requirements and test methods for determining conformance with the
requirements.
1.6 Quality-control measures are to be taken by manufacturers. See Appendix X4 for general information on quality control. 1.7 In referee decisions, the SI units shall be used for metric-sized pipe and inch-pound units for pipe sized in the IPS system (ANSI B36.10) and DIPS system. In all cases, the values given in parentheses are provided for information only. 1.8 The following safety hazards caveat pertains only to the test methods portion, Section 6, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||
|