Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Quantifying Cell Proliferation in 3D Scaffolds by a Nondestructive Method
NORMA vydaná dňa 1.10.2021
Označenie normy: ASTM F3504-21
Dátum vydania normy: 1.10.2021
Kód tovaru: NS-1041790
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cell counting, cell number, cell proliferation, resazurin, stem cells, tissue regeneration,
Adjunct to F3504 Standard Practice for Quantifying Cell Proliferation in 3D Scaffolds by a Nondestructive Method
Vybraný formát:Significance and Use |
5.1?In-vitro cell proliferation assays are used to screen the capability of cells to proliferate and self-renew within scaffolds for regenerative medicine and tissue-engineering applications. The cell proliferation 5.2?Cell proliferation may be an important parameter to test as a quality attribute of a cell-scaffold construct. This test helps to assess cell colonization within a scaffold. 5.3?This method provides a technique for vital assessment and quantification of the fluorescence intensity related to dye metabolism by living and proliferating cells. This method assumes that viable cells will have an active metabolism, which is required to support life-associated cellular processes such as the conversion of nutrient sources into energy and proliferation. There may be cells that are not actively proliferating, yet are still viable within the construct. The methods described within this practice enable nondestructive testing for monitoring the cell proliferation kinetics throughout the culture period by repeated analysis at multiple time points on the same test sample with minimal toxicity. This standard practice is written only for resazurin dye, a non-cytotoxic reagent that should not affect cell viability and proliferation at low concentration. This is a distinct advantage over many other reagents used to measure cell number, such as measurements of the intracellular components (such as DNA, protease, or ATP) which require cell lysis and can therefore only be used for endpoint analysis. 5.4?Resazurin, which has low fluorescence, may be metabolized by cells into resorufin, which is highly fluorescent. An increase in fluorescence caused by the conversion to resorufin may correlate with increased dehydrogenase activity, which may correlate with an increase in cell number and therefore proliferation. Plotting the signals measured at multiple time points enables the generation of proliferation curves. It is important to note that metabolic assays are intended to be measurements of intracellular dehydrogenase or reductase enzyme activity produced by cells. The level of enzyme activity may be directly proportional to the number of viable cells within a range of cell number per volume (or per scaffold) identified by a calibration curve. This is because cell metabolism rate may decrease without a loss in cell viability when cells have reached confluency or when they are differentiating. Some cells may be quiescent but still viable. Furthermore, certain cell types have different metabolic activity. In these situations, the relationship between cell metabolism and cell number may not be linear and other assays may be considered. 5.5?The method may be applied to planar 2D cell cultures and 3D scaffold cell cultures. This assay is intended for 96, 48, and 24-well plates but could work for other size plates. Size and thickness of cell scaffold construct where the test can be applicable should be tested with control experiments. In Reference (4), a 5 mm thick scaffold in a 24-well plate was used. 5.6?The method may also be used to document the absence of cell proliferation in cultures. Note 1:?The absence or suppression of proliferation under the
tested conditions may be a result of lack of reagent/nutrient
diffusion through the scaffold. If so, the same result may not be
observed if diffusion is improved by, for example, changing from a
96-well plate to other cell culture formats.
5.7?The dye is not cell type specific; hence, cell identification cannot be based on this method. 5.8?The assay as described herein is not designed to assess cell distribution in scaffolds. It is possible that this could be achieved by sectioning the scaffolds prior to staining and analysis. |
1. Scope |
1.1?This practice describes how to conduct a nondestructive proliferation test for mammalian cells based on metabolic activity that can be used to assess the number of viable cells within three-dimensional (3D) scaffolds for regenerative medicine and in tissue-engineered medical products (TEMPs). 1.2?This practice provides a detailed explanation of the resazurin cell metabolic activity method in terms of reagent concentrations, incubation times, cell culture media composition, calibration curve, controls, assay linearity, and limitations of the assay. 1.3?This practice describes factors that can interfere with accurate cell proliferation assessment. 1.4?Since the assay has washing steps, it is limited to assessing cells that are immobilized, such as by adhesion to a culture dish, adhesion to a scaffold, or encapsulation in a hydrogel. 1.5?The assay is limited to cell types that can metabolize resazurin to provide a signal in the assay. 1.6?This document does not propose acceptance criteria for a cell-based product based on the application of a cell proliferation test method. 1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |