Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Oxygen Gas Transmission Rate through Plastic Film and Sheeting using a Dynamic Accumulation Method
Automaticky preložený názov:
Štandardná skúšobná metóda pre kyslíka Prenosová rýchlosť cez plastové fólie a paženie pomocou dynamického akumulácie metódy
NORMA vydaná dňa 1.4.2015
Označenie normy: ASTM F3136-15
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2015
Kód tovaru: NS-586291
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Objemová měřicí zařízení pro zpracování ropy a zemního plynu
Keywords:
dynamic accumulation, fluorescence, OTR, oxygen transmission rate, permeability, permeation, plastic film,, ICS Number Code 75.180.30 (Volumetric equipment and measurements)
Significance and Use | ||||||||||
5.1 The Oxygen Transmission Rate is an important determinant of packaging functionality afforded by packaging materials for a wide variety of packaged products including food, pharmaceuticals and medical devices. In some applications, sufficient oxygen must be allowed to permeate into the package. In others, the oxygen ingress must be minimized to maintain product quality. 5.2 Other ASTM Standard Methods to measure the oxygen transmission rate are described in Standard Test Method D3985 and Standard Test Method F2622. |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers a procedure for determination of the transmission rate of oxygen gas through plastics in the form of film, sheeting, laminates, coextrusions, coated or uncoated papers or fabrics. 1.2 This test method is not the only method for measurement of the oxygen transmission rate (OTR). There are other methods of OTR determination that use other oxygen sensors and procedures. 1.3 The values stated in SI units are to be regarded as standard. Commonly used metric units used to report Oxygen Transmission Rate are included in Terminology, Procedure, Precision and Bias sections and in the Calculation section of the Appendix. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Posledná aktualizácia: 2025-01-14 (Počet položiek: 2 219 679)