Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Design, Manufacture, Installation, Operation, Maintenance, Inspection and Major Modification of Trampoline Courts
NORMA vydaná dňa 1.2.2020
Označenie normy: ASTM F2970-20
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.2.2020
Kód tovaru: NS-983452
Počet strán: 33
Približná hmotnosť: 99 g (0.22 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aerobics, amusement device, basketball, children zone, construction, court attendant, design, dodgeball, family entertainment center, fitness center, foam pit, gym, gymnastics, inspection, institutional trampoline, jump center, maintenance, operation, recreational equipment, slam dunk, sports court, sports equipment, trampoline arena, trampoline court, trampoline equipment, trampoline park, volleyball,, ICS Number Code 97.220.99 (Other sports equipment and facilities)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||
4.1 This practice is intended to provide consistent criteria, references and operational considerations in the specifications, management and construction of institutional trampoline courts. 4.2 This practice is intended to be taken into consideration by architects, designers, engineers, construction contractors, manufacturers, appropriate inspectors, owners and operators who are involved with the design, construction, manufacture, installation, operation, maintenance, inspection or major modification of institutional trampoline courts. 4.3 This practice does not apply to consumer trampolines, trampolines intended for use on water, trampolines intended for use as aquatic play equipment, trampolines primarily used for professional exhibition, or single user trampolines primarily used under the direct supervision of a trainer or coach. 4.4 This standard does not apply to stand alone institutional trampoline units that consist of one or more individual stations with a total bed area less than 37 000 in.2 (238 709.2 cm2) and employ a mechanical harnessed system to control or direct the descent of a patron. 4.5 This standard does not apply to stand alone institutional trampoline units that consist of one or more individual stations with a total bed area less than 37 000 in.2 (238 709.2 cm2) and employ individual chambers divided with small mesh netting to control or direct the descent of a patron. 4.6 This standard does not apply to inflatable amusement devices covered by Practice F2374. 4.6.1 This standard applies to trampoline courts that mount or dismount onto an inflatable impact attenuation system. 4.7 Trampoline courts that employ a device designed to introduce additional energy into the suspension or bed system are outside the scope of this standard practice. 4.8 For the purpose of this standard, consideration shall be given within the design and for operation of a trampoline court with activities including but not limited to: bouncing, jumping, walking, standing, sitting, resting, acrobatic maneuvers, aerobics, flips, dancing, exercise, therapeutic rehabilitation, dodgeball, basketball, or volleyball. 4.9 For the purpose of this standard, consideration shall be given within the design and for operation of a trampoline court with complementary equipment including but not limited to: foam balls, inflated balls, foam toys, wakeboards, snowboards, bounce boards, hoops, nets, pylons, ropes, goals, harness systems, or inflated toys. |
||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||
1.1 The purpose of this practice is to delineate requirements regarding the design, manufacture, installation, operation, maintenance, inspection and major modification of commercial or institutional trampoline courts with the primary purpose of amusement, entertainment or recreation. 1.2 This standard applies to institutional trampoline courts that are located in and around amusement, entertainment or recreational facilities. Such facilities include but are not limited to trampoline parks, amusement parks, theme parks, water parks, family entertainment centers, fitness centers, gyms, gymnastics facilities, sports facilities, skate parks, camps, shopping centers, temporary special events, carnivals and municipal parks. 1.3 This standard applies to devices manufactured on or after the date of publication of this standard practice. 1.4 This practice establishes guidelines that will provide a level of conformity for the purpose of reducing potential hazards to patrons, court attendants, and spectators. 1.5 This standard does not purport to address all of the hazards associated with institutional trampoline courts. The standard’s existence alone will not prevent injuries. Like other physical activities, institutional trampoline court use involves the risk of injury, particularly if the equipment is used improperly or if users exceed their capabilities, endurance, training, or experience. 1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. 1.7 This practice includes an annex (mandatory), which provides additional information (for example, rationale, background, interpretations, drawings, commentary, and so forth) to improve the user’s understanding and application of the criteria presented in this practice. The annex information shall be interpreted as mandatory criteria. 1.8 This practice includes an appendix (non-mandatory), which provides additional information (for example, rationale, background, interpretations, drawings, commentary, and so forth) to improve the user’s understanding and application of the criteria presented in this practice. The appendix information shall not be interpreted as mandatory criteria. 1.9 This standard includes the following sections:
1.10 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.11 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.12 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||
|
Posledná aktualizácia: 2024-12-23 (Počet položiek: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.