Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Rehabilitation of a Sewer Service Lateral and Its Connection to the Main Using a One Piece Main and Lateral Cured-in-Place Liner
Automaticky preložený názov:
Štandardné praktiky pre rehabilitáciu kanalizačné služby bočné a jeho pripojenie k hlavnému Použitím One Piece hlavnej a priečnej vytvrdzovanými na Place Liner
NORMA vydaná dňa 1.12.2011
Označenie normy: ASTM F2561-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2011
Kód tovaru: NS-54133
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
ambient cure, continuous, cured-in-place pipe, epoxy, felt, hydrophilic o-rings, inflation, inversion, knit, lateral identification, lateral pipe, lateral tube, launcher, liner/bladder assembly, main pipe, main sheet, main to lateral connection, MLCIPL, one-piece, resin, sewer lateral lines, sheet, steam cure, TEE, textile sheet, textile tube, transition, translucent bladder, tube, vacuum impregnate, WYE, ICS Number Code 93.030 (External sewerage systems)
Significance and Use | ||||||||||||||||
This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations who are involved in the rehabilitation of sewer service laterals and its connection to the main through the use of a resin-impregnated tube installed within an existing sewer lateral. As for any practice, modifications may be required for specific job conditions. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice covers requirements and test methods for the reconstruction of a sewer service lateral pipe having an inner diameter of 3 to 12 in. and its connection to the main pipe having an inner diameter of 6 to 24 in. without excavation. The lateral pipe is accessed remotely from the main pipe and from a lateral cleanout. This will be accomplished by the installation of a resin impregnated one-piece main and lateral cured in-place lining (MLCIPL) by means of air or water inflation and inversion. The MLCIPL is pressed against the host pipe by pressurizing a bladder and is held in place until the thermoset resins have cured. When cured, the MLCIPL shall be a continuous, one piece, tight fitting, corrosion resistant lining extending over a predetermined length of the lateral pipe and the adjacent section of the main pipe providing a verifiable non-leaking structural connection and seal. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only. 1.3 There is no similar or equivalent ISO Standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Historická
1.9.2011
Historická
1.7.2013
Historická
1.7.2013
Historická
1.5.2008
Historická
1.8.2011
Historická
1.4.2010
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-26 (Počet položiek: 2 217 217)
© Copyright 2024 NORMSERVIS s.r.o.