Standard Test Method for Extracting Residue from Metallic Medical Components and Quantifying via Gravimetric Analysis
Automaticky preložený názov:
Štandardná skúšobná metóda pre Ťažba rezíduí z kovových Lekárske komponenty a kvantifikácia cez Gravimetrická analýza
NORMA vydaná dňa 1.8.2005
Označenie normy: ASTM F2459-05
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.8.2005
Kód tovaru: NS-53919
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
extractable residue, gravimetric analysis, metallic medical components, non-soluble extractables, non-soluble debris, water soluble extractables, ICS Number Code 11.100.99 (Other standards related to laboratory medicine)
Significance and Use | ||||||||||
This test method is suitable for determination of the extractable residue in metallic medical components. Extractable residue includes aqueous and non-aqueous residue, as well as non-soluble residue. This test method recommends the use of a sonication technique to extract residue from the medical component. Other techniques, such as solvent reflux extraction, could be used but have been shown to be less efficient in some tests, as discussed in X1.2. This test method is not applicable for evaluating the extractable residue for the reuse of a single-use component (SUD). |
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the quantitative assessment of the amount of residue obtained from metallic medical components when extracted with aqueous or organic solvents. 1.2 This test method does not advocate an acceptable level of cleanliness. It identifies one technique to quantify extractable residue on metallic medical components. In addition, it is recognized that this test method may not be the only method to determine and quantify extractables. 1.3 Although these methods may give the investigator a means to compare the relative levels of component cleanliness, it is recognized that some forms of component residue may not be accounted for by these methods. 1.4 The applicability of these general gravimetric methods have been demonstrated by many literature reports; however, the specific suitability for applications to all-metal medical components will be validated by an Interlaboratory Study (ILS) conducted according to Practice E 691. 1.5 This test method is not intended to evaluate the residue level in medical components that have been cleaned for reuse. This test method is also not intended to extract residue for use in biocompatibility testing. 1.6 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.7 This standard may involve hazardous or environmentally-restricted materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.