Standard Specification for Metal Insert Fittings for Polyethylene/Aluminum/Polyethylene and Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene Composite Pressure Pipe
Automaticky preložený názov:
Štandardné špecifikácie pre kovovú vložkou Kovanie pre PET / hliník / polyetylén a zosietený polyetylén / hliník / zosietený polyetylén Composite výtlačného potrubia
NORMA vydaná dňa 10.4.2001
Označenie normy: ASTM F1974-01
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.4.2001
Kód tovaru: NS-52303
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cold and hot water distribution, copper crimp rings, crosslinked polyethylene, metal insert fittings, polyethylene, PE/AL/PE, PEX/AL/PEX, PAP
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This specification covers metal insert fittings with split ring and compression nut (compression joint) and metal insert fittings with copper crimp rings (crimp joint) for four sizes of composite pressure pipe. These fittings are intended for use in 125 psi (690 kPa) cold- and hot-water distribution systems operating at temperatures up to and including 180o F (82oC). (When used in polyethylene/aluminum/polyethylene systems the maximum operating temperature is limited by the pipe to 140 F (60oC) and where applicable 180oF (82oC)). Included are the requirements for materials, workmanship, burst pressure, sustained pressure, excessive temperature and pressure, temperature cycling tests, and markings to be used on the fittings and rings. The fittings covered by this specification are intended for use in potable water distribution systems for residential and commercial applications, water service, underground irrigation systems, and radient panel heating systems, baseboard, snow- and ice-melt systems, and gases that are compatible with the composite pipe and fittings. 1.2 The values stated in inch-pound units are to be regarded as the standard. The SI values stated in parentheses are provided for information purposes. Note 1—The tables show the "nominal size" in millimetres with the inch size in parentheses. This exception is made to harmonize the "nominal size" with the two pipe standards, F1281 and F1281. 1.3 The following precautionary caveat pertains only to the test method portion, Section 9, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|