Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Trace Metallic Impurities in Electronic Grade Aluminum by High Mass-Resolution Glow-Discharge Mass Spectrometer
Automaticky preložený názov:
Štandardná skúšobná metóda pre Trace kovových nečistôt v elektronickej kvalitného hliníka od High Mass-Resolution Glow vybíjanie Mass Spectrometer
NORMA vydaná dňa 15.6.2008
Označenie normy: ASTM F1593-08
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.6.2008
Kód tovaru: NS-50852
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aluminum, electronics, glow discharge mass spectrometer (GDMS), purity analysis, sputtering target, trace metallic impurities, Aluminum electrical conductors (semiconductors), Glow discharge mass spectrometer (GDMS), High-purity aluminum, Impurities--electronic materials/applications, Mass spectrometry--electronic materials/applications, Purity analysis--electronic materials/applications, Sputtering process/targets, Trace metallic impurities
Significance and Use | ||||||||
This test method is intended for application in the semiconductor industry for evaluating the purity of materials (for example, sputtering targets, evaporation sources) used in thin film metallization processes. This test method may be useful in additional applications, not envisioned by the responsible technical committee, as agreed upon by the parties concerned. This test method is intended for use by GDMS analysts in various laboratories for unifying the protocol and parameters for determining trace impurities in pure aluminum. The objective is to improve laboratory to laboratory agreement of analysis data. This test method is also directed to the users of GDMS analyses as an aid to understanding the determination method, and the significance and reliability of reported GDMS data. For most metallic species the detection limit for routine analysis is on the order of 0.01 weight ppm. With special precautions detection limits to sub-ppb levels are possible. This test method may be used as a referee method for producers and users of electronic-grade aluminum materials. |
||||||||
1. Scope | ||||||||
1.1 This test method covers measuring the concentrations of trace metallic impurities in high purity aluminum. 1.2 This test method pertains to analysis by magnetic-sector glow discharge mass spectrometer (GDMS). 1.3 The aluminum matrix must be 99.9 weight % (3N-grade) pure, or purer, with respect to metallic impurities. There must be no major alloy constituent, for example, silicon or copper, greater than 1000 weight ppm in concentration. 1.4 This test method does not include all the information needed to complete GDMS analyses. Sophisticated computer-controlled laboratory equipment skillfully used by an experienced operator is required to achieve the required sensitivity. This test method does cover the particular factors (for example, specimen preparation, setting of relative sensitivity factors, determination of sensitivity limits, etc.) known by the responsible technical committee to affect the reliability of high purity aluminum analyses. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
1.10.2007
Historická
15.3.2007
Historická
1.10.2008
Historická
1.10.2012
Historická
1.9.2011
Historická
1.2.2008
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-01 (Počet položiek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.