Standard Guide for Background Subtraction Techniques in Auger Electron Spectroscopy and X-ray Photoelectron Spectroscopy
Automaticky preložený názov:
Štandardné Sprievodca pre odčítanie pozadia technikách v Auger elektrónové spektroskopia a X - ray fotoelektronové spektroskopia
NORMA vydaná dňa 1.7.2004
Označenie normy: ASTM E995-04
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.7.2004
Kód tovaru: NS-48725
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Auger electron spectroscopy, background subtraction, surface analysis, X-ray photoelectron spectroscopy, ICS Number Code 17.180.30 (Optical measuring instruments)
Significance and Use | ||||
Background subtraction techniques in AES were originally employed as a method of enhancement of the relatively weak Auger signals to distinguish them from the slowly varying background of secondary and backscattered electrons. Interest in obtaining useful information from the Auger peak line shape, concern for greater quantitative accuracy from Auger spectra, and improvements in data gathering techniques, have led to the development of various background subtraction techniques. Similarly, the use of background subtraction techniques in XPS has evolved mainly from the interest in the determination of chemical states (binding energy values), greater quantitative accuracy from the XPS spectra, and improvements in data acquisition. Post-acquisition background subtraction is normally applied to XPS data. The procedures outlined are popular in XPS and AES. General reviews of background subtraction techniques have been published (1 and 2 ).3 |
||||
1. Scope | ||||
1.1 The purpose of this guide is to familiarize the analyst with the principal background subtraction techniques presently in use together with the nature of their application to data acquisition and manipulation. 1.2 This guide is intended to apply to background subtraction in electron, X-ray, and ion-excited Auger electron spectroscopy (AES), and X-ray photoelectron spectroscopy (XPS). 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-07-04 (Počet položiek: 2 207 347)
© Copyright 2025 NORMSERVIS s.r.o.