Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of the Spectral Mismatch Parameter Between a Photovoltaic Device and a Photovoltaic Reference Cell
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie spektrálne Nesúlad parameter medzi fotovoltaického zariadenia a fotovoltaické odkaz na bunku
NORMA vydaná dňa 1.6.2010
Označenie normy: ASTM E973-10
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2010
Kód tovaru: NS-48664
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cell, mismatch, photovoltaic, reference, solar, spectral, testing, Photovoltaic (PV) power systems, Solar collectors, Solar spectral irradiance, Spectral data--solar devices, Spectral mismatch parameter, ICS Number Code 27.160 (Solar energy engineering)
Significance and Use | ||||||||||||||||||||
The calculated error in the photovoltaic device current determined from the spectral mismatch parameter can be used to determine if a measurement will be within specified limits before the actual measurement is performed. The spectral mismatch parameter also provides a means of correcting the error in the measured device current due to spectral mismatch. The spectral mismatch parameter is formulated as the fractional error in the short-circuit current due to spectral differences. , Error due to spectral mismatch can be corrected by dividing the measured photovoltaic cell current by M, a procedure used in Test Methods E948 and E1036. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method covers a procedure for the determination of a spectral mismatch parameter used in performance testing of photovoltaic devices. 1.2 The spectral mismatch parameter is a measure of the error, introduced in the testing of a photovoltaic device, caused by mismatch between the spectral responses of the photovoltaic device and the photovoltaic reference cell, as well as mismatch between the test light source and the reference spectral irradiance distribution to which the photovoltaic reference cell was calibrated. Examples of reference spectral irradiance distributions are Tables E490 or G173. 1.3 The spectral mismatch parameter can be used to correct photovoltaic performance data for spectral mismatch error. 1.4 This test method is intended for use with linear photovoltaic devices. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-15 (Počet položiek: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.