Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Measurement of Mechanical Properties During Charged-Particle Irradiation
NORMA vydaná dňa 1.1.2023
Označenie normy: ASTM E821-16(2023)
Dátum vydania normy: 1.1.2023
Kód tovaru: NS-1099433
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
This practice covers the measurement of the mechanical properties of materials during charged-particle irradiation, with the test materials designed to simulate or provide understanding of, or both, the mechanical behavior of materials when exposed to neutron irradiation. This practice includes requirements for test material and particle beam characterization (such as for strain, load, temperature monitoring and control, and specimen environment monitoring), and recommended procedures for measuring mechanical properties and for calculating radiation damage (such as particle ranges, damage energy, damage rates, and damage gradients). Methods for comparing ion damage with neutron damage are also recommended.
Keywords:
accelerators, beam heating, in situ measurements, ion irradiation, mechanical properties, radiation damage simulation,, ICS Number Code 19.100 (Non-destructive testing)
1. Scope | ||||
1.1?This practice covers the performance of mechanical tests on materials being irradiated with charged particles. These tests are designed to provide an understanding of the effects of neutron irradiation on the mechanical behavior of materials. Practices are described that govern the test material, the particle beam, the experimental technique, and the damage calculations. Reference should be made to other ASTM standards, especially Practice E521. Procedures are described that are applicable to creep and creep rupture tests made in tension and torsion test modes.1.2?The word simulation is used here in a broad sense to imply an approximation of the relevant neutron irradiation environment. The degree of conformity can range from poor to nearly exact. The intent is to produce a correspondence between one or more aspects of the neutron and charged-particle irradiations such that fundamental relationships are established between irradiation or material parameters and the material response. 1.3?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||
2. Referenced Documents | ||||
|