Standard Test Method for Limiting Oxygen (Oxidant) Concentration of Combustible Dust Clouds
Automaticky preložený názov:
Štandardná skúšobná metóda pre obmedzenie kyslík (Oxidant) Koncentrácia horľavého prachu mraky
NORMA vydaná dňa 1.6.2013
Označenie normy: ASTM E2931-13
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2013
Kód tovaru: NS-46279
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
inerting, limiting oxygen concentration, dust explosions, ICS Number Code 13.230 (Explosion protection)
Significance and Use | ||||||||||||||||||
5.1 This test method provides a procedure for performing laboratory tests to evaluate relative deflagration parameters of dusts. 5.2 Knowledge of the limiting oxygen (oxidant) concentration is needed for safe operation of some chemical processes. This information may be needed in order to start up, shut down or operate a process while avoiding the creation of flammable dust-gas atmospheres therein, or to pneumatically transport materials safely. NFPA 69 provides guidance for the practical use of LOC data, including the appropriate safety margin to use. 5.3 Since the LOC as measured by this method may vary with the energy of the ignitor and the propagation criteria, the LOC should be considered a relative rather than absolute measurement. 5.4 If too weak an ignition source is used, the measured LOC would be higher than the “true” value and would not be sufficiently conservative. This is an ignitability limit rather than a flammability limit, and the test could be described as “underdriven.” Ideally, the ignition energy is increased until the measured LOC is independent of ignition energy (that is, the “true” value). However, at some point the ignition energy may become too strong for the size of the test chamber, and the system becomes “overdriven.” When the ignitor flame becomes too large relative to the chamber volume, a test could appear to result in an explosion, while it is actually just dust burning in the ignitor flame with no real propagation beyond the ignitor 5.5 The recommended ignition source for measuring the LOC of dusts in 20-L chambers is a 2500-J pyrotechnic ignitor.5.6 The values obtained by this testing technique are specific to the sample tested (particularly the particle size distribution) and the method used and are not to be considered intrinsic material constants. 1.1 This test method is designed to
determine the limiting oxygen concentration of a combustible dust
dispersed in a mixture of air with an inert/nonflammable gas in a
near-spherical closed vessel of 20 L or greater volume.
1.2 Data obtained from this method provide a relative measure of the deflagration characteristics of dust clouds. 1.3 This test method should be used to measure and describe the properties of materials in response to heat and flame under controlled laboratory conditions and should not be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test may be used as elements of a fire risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Test Method for Minimum
Explosible Concentration of Combustible Dusts Standard Test Method for Explosibility of
Dust Clouds Standard Practice for Use of the Terms
Precision and Bias in ASTM Test Methods Standard Practice for Conducting an
Interlaboratory Study to Determine the Precision of a Test
Method EN 14034–4 Determination of the explosion
characteristics of dust clouds--Part 4: Determination of the
limiting oxygen concentration LOC of dust clouds Standard Test Method for Moisture in the
Analysis Sample of Coal and Coke Standard Test Methods for Limiting Oxygen
(Oxidant) Concentration in Gases and Vapors NFPA 69 Standard on Explosion Prevention
Systems Standard Test Method for Volatile Matter
in the Analysis Sample of Coal and Coke |
Historická
15.2.2012
Historická
1.2.2014
Historická
1.7.2011
Historická
1.4.2008
Historická
1.10.2009
Historická
1.5.2013
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-13 (Počet položiek: 2 210 764)
© Copyright 2024 NORMSERVIS s.r.o.