Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
Automaticky preložený názov:
Štandardná skúšobná metóda na stanovenie miery Air presakovaniu cez Vonkajší Windows , obvodových plášťov , a dvere za stanovených tlakových rozdielov medzi exempláre
NORMA vydaná dňa 10.4.1999
Označenie normy: ASTM E283-91(1999)
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.4.1999
Kód tovaru: NS-46102
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Air leakage testing-building materials/constructions, Building constructions/materials-curtain walls, Building constructions/materials-doors, Building constructions/materials-windows, Leak testing, Leak testing-building constructions/materials, air leakage through exterior windows/curtain walls/doors under specified, pressure differences across specimen, test, ICS Number Code 91.120.10 (Thermal insulation of buildings)
| 1. Scope | ||||
|
1.1 This test method provides a standard laboratory procedure for determining the air leakage rates of exterior windows, curtain walls, and doors under specified differential pressure conditions across the specimen. The test method described is for tests with constant temperature and humidity across the specimen. 1.2 This laboratory procedure is applicable to exterior windows, curtain walls, and doors and is intended to measure only such leakage associated with the assembly and not the installation. The test method can be adapted for the latter purpose. Note 1-Performing tests at non-ambient conditions or with a temperature differential across the specimen may affect the air leakage rate. This is not addressed by this test method.1.3 This test method is intended for laboratory use. Persons interested in performing field air leakage tests on installed units should reference Method E783. 1.4 Persons using this procedure should be knowledgeable in the areas of fluid mechanics, instrumentation practices, and shall have a general understanding of fenestration products and components. 1.5 Throughout this test method, SI units are listed first in accordance with E-6 metric policy, and shall be considered the primary units. Non-SI units are provided in parenthesis. 1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement see Section 7. |
||||
| 2. Referenced Documents | ||||
|
Posledná aktualizácia: 2025-11-16 (Počet položiek: 2 243 995)
© Copyright 2025 NORMSERVIS s.r.o.