Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Test Method for Atom Percent Fission in Uranium and Plutonium Fuel (Mass Spectrometric Method) (Withdrawn 2001)
Automaticky preložený názov:
Skúšobná metóda pre Atom Percento štiepenie uránu a plutónia paliva ( hmotnostná spektrometria v Method ) ( Withdrawn 2001 )
NORMA vydaná dňa 27.2.1997
Označenie normy: ASTM E244-80(1995)
Poznámka: NEPLATNÁ
Dátum vydania normy: 27.2.1997
Kód tovaru: NS-45305
Počet strán: 5
Približná hmotnosť: 15 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Atom percent fission-uranium/plutonium fuel, Heavy element atom percent fission, Irradiance/irradiation, Mass spectrometry, Nuclear fuels (reactor), Uranium, heavy element atom percent fission in irradiated uranium/plutonium fuel,, by mass spectrometric method, test, ICS Number Code 27.120.30 (Fissile materials and nuclear fuel technology)
1. Scope |
1.1 This test method covers the determination of the heavy element atom percent fission in irradiated uranium (U) fuel with initial plutonium (Pu) content from 0 to 50% from isotopic analyses of the fuel before and after irradiation (1,2). 1.2 The test method specifies the computational procedures for handling mass spectrometric analyses. Chemical separation procedures and mass spectrometer operation procedures are specified in Test Method E267. 1.3 The test method is applicable to thermal-reactor U and Pu fuels but does not apply to fuels containing thorium or U before irradiation. 1.4 The determination of burnup from changes in isotopic composition has several requirements that limit its usefulness and accuracy. The most obvious requirement is the availability of a pre-irradiation specimen which truly represents the sample to be analyzed. A second limiting requirement is the availability of correct neutron-spectrum-dependent reactor parameters, especially capture-to-fission ratios for U, Pu, and Pu. Finally, many additional factors implicitly assumed to be negligible in this treatment become significant at high exposures. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Posledná aktualizácia: 2024-11-01 (Počet položiek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.