Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Reference Radiographs for Appearances of Radiographic Images as Certain Parameters are Changed
Automaticky preložený názov:
Štandardné Referenčné Röntgenové snímky pre vystúpenie rádiografického snímok ako určité parametre sú zmenené
NORMA vydaná dňa 1.6.2015
Označenie normy: ASTM E242-15
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2015
Kód tovaru: NS-610689
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
film systems, discontinuities, gamma rays, reference radiographs, steel, unsharpness, welds, x-ray ,, ICS Number Code 19.100 (Non-destructive testing)
Significance and Use | ||||||||||||
4.1 A key consideration with any radiographic system is its contrast resolution and spatial resolution capability (that is, sensitivity). The degree of obtainable sensitivity with a given system is dependent upon several radiographic parameters such as source energy level, film system class, type and thickness of intensifying screens, and material thickness radiographed. These reference radiographs permit the user to estimate the degree of sensitivity change that may be obtained when these parameters are varied from a specific technique. This standard may also be used in conjunction with Test Method E1815 or with Practice E746 or Test Method E1735 to provide a basis for developing data for evaluation of a user's specific system. This data may assist a user in determining appropriate parameters for obtaining desired degrees of radiographic system sensitivity. |
||||||||||||
1. Scope | ||||||||||||
1.1 This document describes the appearance of a radiographic image where fundamental components of image quality are changed, that is, variables such as whether an X-ray or gamma ray source was used, the characteristics of the radiographic film (gradient, granularity, and developing conditions) and intensifying screens, and specimen thickness (the geometrical configuration of the radiographic set-up and focal spot size both affect image quality but are not considered in the reference radiographs). 1.2 The X-ray film systems used in obtaining the illustrative data were as follows: Very Fine Grain (comparable to class I of Test Method E1815) and Fine Grain (comparable to class II of Test Method E1815). 1.3 These reference radiographs1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Posledná aktualizácia: 2024-04-26 (Počet položiek: 2 896 057)
© Copyright 2024 NORMSERVIS s.r.o.