Standard Quantitative Carrier Test Method To Evaluate the Bactericidal, Fungicidal, Mycobactericidal and Sporicidal Potencies of Liquid Chemical Germicides
Automaticky preložený názov:
Štandardné Kvantitatívne Carrier testovacia metóda pre stanovenie baktericídne, fungicídne , Mykobakteriocidný a sporicidní potencie kvapalných chemických germicid
NORMA vydaná dňa 10.10.2000
Označenie normy: ASTM E2111-00
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.10.2000
Kód tovaru: NS-44335
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Bacillus subtilis spores, bactericides, chemical germicides, Clostridium sporogenes spores, eluate, eluent, environmental surfaces, fungicides, log10 reductions, medical devices, membrane filtration, mycobactericides, Mycobacterium terrae, Pseudomonas aeruginosa, quantitative carrier test, soil load, sporicides, Staphylococcus aureus, standard hard water, surrogate, Trichophyton mentagrophytes conidia, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
1. Scope | ||||||||||||
1.1 This test method is designed for use in product development and for the generation of product potency data. The loading of each carrier with a known volume of the test organism suspension is possible. The incorporation of control carriers also allows for an assessment of the load of viable test organism on the test carriers. 1.2 This test method is designed to have survivors and also to be used with a performance standard. The surviving microorganisms on each test carrier are compared to the mean of no less than three control carriers to determine if the performance standard has been met. To allow proper statistical evaluation of results, the size of the test inoculum should be sufficiently large to take into account both the performance standard and the experimental variation in the results. For example, if an arbitrary performance standard of 6-log10 reduction in the viability titer of the test organism is used, and an inoculum size of 107 CFU, then theoretically a maximum of ten survivors per carrier is permitted; however, because of experimental variability the exact target may need to be higher than 106 CFU/carrier, thus fewer survivors would be permitted. 1.3 This test method should be performed by persons with training in microbiology and in facilities designed and equipped for work with infectious agents at the appropriate biosafety level (3). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5 In this test method, metric units are used for all applications, except for distance in which case inches are used and metric units follow. 1.6 It is the responsibility of the investigator to determine whether Good Laboratory Practice Regulations (GLPs) are required and to follow them where appropriate (40 CFR, Part 160 for EPA submissions and 21 CFR, Part 58 for FDA submissions). |
||||||||||||
2. Referenced Documents | ||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-07-09 (Počet položiek: 2 207 504)
© Copyright 2025 NORMSERVIS s.r.o.