Standard Practice for General Techniques of Liquid Chromatography-Infrared (LC/IR) and Size Exclusion Chromatography-Infrared (SEC/IR) Analyses
Automaticky preložený názov:
Štandardné praktiky pre všeobecné Techniky kvapalinovej chromatografie-infračervené (LC / IR) a vylučovacie chromatografiu-infračervené (SEC / IR) Analýzy
NORMA vydaná dňa 1.11.2011
Označenie normy: ASTM E2106-00(2011)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2011
Kód tovaru: NS-44315
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
infrared spectroscopy, LC/IR, liquid chromatography, SEC/IR, Flowcell detection, Infrared (IR) analysis--metals/alloys, LC/IR (liquid chromatography/infrared analysis), Liquid chromatography (LC), Eluent trapping techniques, Qualitative analysis/measurement, Quantitative analysis/measurement, Size-exclusion chromatography (SEC), Software treatment (of infrared data), ICS Number Code 71.040.30 (Chemical reagents)
Significance and Use | ||||||||
This practice provides general guidelines for the practice of liquid chromatography or size exclusion chromatography coupled with infrared spectrometric detection and analysis (LC/IR, SEC/IR). This practice assumes that the chromatography involved is adequate to resolve a sample into discrete fractions. It is not the intention of this practice to instruct the user on how to perform liquid or size exclusion chromatography (LC or SEC). |
||||||||
1. Scope | ||||||||
1.1 This practice covers techniques that are of general use in qualitatively analyzing multicomponent samples by using a combination of liquid chromatography (LC) or size exclusion chromatography (SEC) with infrared (IR) spectrometric techniques. The sample mixture is separated into fractions by the chromatographic separation. These fractions are subsequently analyzed by an IR spectroscopic method. 1.2 Three different types of LC/IR techniques have been used to analyze samples (1, 2). These consist of eluent trapping (see Practices E334), flowcell and direct deposition. These are presented in the order that they were first used. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||