Standard Test Method for Size-Differentiated Counting of Particles and Fibers Released from Cleanroom Wipers Using Optical and Scanning Electron Microscopy
Automaticky preložený názov:
Štandardná skúšobná metóda pre veľkosť rozlíšené počítanie častíc a vlákien prepustený z Cleanroom stierače pomocou optického a Snímacie elektrónové mikroskopie
NORMA vydaná dňa 1.4.2012
Označenie normy: ASTM E2090-12
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.4.2012
Kód tovaru: NS-44254
Počet strán: 11
Približná hmotnosť: 33 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
cleanroom wipers, contamination control, membrane filter, optical microscopy, particle counting and sizing, particles and fibers, scanning electron microscopy, Cleanrooms (materials/applications), Fiber analysis, Optical electron microscopy, Particle counters/counting, Scanning electron microscope (SEM), Size-diferentiated counting, ICS Number Code 13.040.35 (Cleanrooms and associated controlled environments)
Significance and Use | ||||||
This test method provides for accurate and reproducible enumeration of particles and fibers released from a wiper immersed in a cleaning solution with moderate mechanical stress applied. When performed correctly, this counting test method is sensitive enough to quantify very low levels of total particle and fiber burden. The results are accurate and not influenced by artifact or particle size limitations. A further advantage to this technique is that it allows for morphological as well as X-ray analysis of individual particles. |
||||||
1. Scope | ||||||
1.1 This test method covers testing all wipers used in cleanrooms and other controlled environments for characteristics related to particulate cleanliness. 1.2 This test method includes the use of computer-based image analysis and counting hardware and software for the counting of densely particle-laden filters (see 7.7-7.9). While the use of this equipment is not absolutely necessary, it is strongly recommended to enhance the accuracy, speed, and consistency of counting. 1.3 The values stated in SI units are to be regarded as the standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||