Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers
Automaticky preložený názov:
Štandardná prax pre meranie a kompenzáciu priepustnosť poľahčujúce médiá pomocou termovíznych rádiometre
NORMA vydaná dňa 1.12.2014
Označenie normy: ASTM E1897-14
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.12.2014
Kód tovaru: NS-43490
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
attenuating medium, blackbody simulator, emissivity, filter, imaging, infrared, infrared examination, infrared testing, infrared thermography, nondestructive testing, radiometry, reflected temperature, temperature compensation, transmittance, temperature measurement, window,, ICS Number Code 17.200.10 (Heat. Calorimetry)
Significance and Use | ||
5.1 The transmittance of an attenuating medium can cause errors for an infrared thermographer using an infrared imaging radiometer to measure the temperature of a specimen through the medium. Three test methods are given for measuring and compensating for this error source. 5.1.1 A procedure is given for measuring the transmittance of an attenuating medium. 5.1.2 A procedure is given for compensating for errors when measuring the temperature of a specimen having a known emissivity through an attenuating medium with a known transmittance. 5.1.3 A procedure is given for measuring and compensating for transmittance and emissivity errors when the specimen temperature is known. 5.2 These procedures can be used in the field or laboratory using commonly available materials. 5.3 These procedures can be used with any infrared radiometers that have the required computer capabilities. 5.4 The values of transmittance are defined only in terms of the procedure for the purpose of process control and nondestructive evaluation of materials. |
||
1. Scope | ||
1.1 This practice covers procedures for measuring and compensating for transmittance when using an infrared imaging radiometer to measure the temperature of a specimen through an attenuating medium, such as a window, filter or atmosphere.1.2 The values stated in SI units are to be regarded as the standard. 1.3 These procedures may involve use of equipment and materials in the presence of heated or electrically-energized equipment, or both. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Historická
1.9.2013
Historická
1.9.2012
Historická
1.3.2011
Historická
1.11.2010
Historická
15.1.2015
Historická
15.9.2013
Poskytovanie aktuálnych informácií o legislatívnych predpisoch vyhlásených v Zbierke zákonov od roku 1945.
Aktualizácia 2x v mesiaci !
Chcete vedieť viac informácii ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-05-04 (Počet položiek: 2 198 283)
© Copyright 2025 NORMSERVIS s.r.o.