Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Sensory Analysis´Triangle Test
NORMA vydaná dňa 15.8.2018
Označenie normy: ASTM E1885-18
Dátum vydania normy: 15.8.2018
Kód tovaru: NS-857435
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
difference testing, discrimination test, sensory analysis, similarity testing, triangle test,, ICS Number Code 67.240 (Sensory analysis)
Significance and Use | ||||||||
5.1 This test method is effective for the following test objectives: 5.1.1 To determine whether a perceivable difference results or a perceivable difference does not result, for example, when a change is made in ingredients, processing, packaging, handling or storage; or 5.1.2 To select, train and monitor assessors. 5.2 This test method itself does not change whether the purpose of the triangle test is to determine that two products are perceivably different versus that the products are not perceivably different. Only the selected values of 1.1 This test method covers a procedure for determining whether a perceptible sensory difference exists between samples of two products. 1.2 This test method applies whether a difference may exist in a single sensory attribute or in several. 1.3 This test method is applicable when the nature of the difference between the samples is unknown. It does not determine the size or the direction of the difference. The attribute(s) responsible for the difference are not identified. 1.4 Compared to the duo-trio test, the triangle test can achieve an equivalent level of statistical significance with fewer assessors. For details on how the triangle test compares to other three-sample tests, see Refs (1) , (2), (3) and (4).2 1.5 This test method is applicable only if the products are homogeneous. If two samples of the same product can often be distinguished, then another method, for example, descriptive analysis, may be more appropriate. 1.6 This test method is applicable only when the products do not cause excessive sensory fatigue, carryover or adaptation. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||
2. Referenced Documents | ||||||||
|
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.