Standard Test Method for Evaluation of Antimicrobial Formulations by the Agar Patch Technique
Automaticky preložený názov:
Štandardné testovacie metódy na hodnotenie antimikrobiálne formulácií podľa Agar Patch Technika
NORMA vydaná dňa 1.11.2005
Označenie normy: ASTM E1882-05
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2005
Kód tovaru: NS-43438
Počet strán: 4
Približná hmotnosť: 12 g (0.03 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
agar patch, antibacterial, control formulation, resident microorganism, persistent activity, transient microorganism, ICS Number Code 71.100.40 (Surface active agents)
| Significance and Use | ||
|
This procedure can be used to evaluate formulations containing ingredients intended to inhibit growth of bacteria on intact skin and measures the difference, post-product-exposure, between numbers of bacterial colonies on active test formulation plates and numbers on control plates, expressed as percent inhibition. This procedure may also be used to test for persistence of activity, as a function of time elapsed between application of active test formulation and application of active test plates. Because no procedure for neutralization of the antimicrobial action of active ingredients can be included in the test, the agar patch method is limited to the extent that results expressed as percent inhibition do not differentiate between bacteriostatic and bacteriocidal effects and, hence, must not be portrayed as “reductions.” |
||
| 1. Scope | ||
|
1.1 This test method determines the antibacterial activity and persistence of test formulations, as measured by the inhibition of a test organism on an agar surface exposed to test sites on human skin treated with the formulations. 1.2 A knowledge of microbiological techniques is required for these procedures. 1.3 It is the responsibility of the investigator to determine if Good Laboratory Practice (GLP) and Good Clinical Practice (GCP) are required and to adhere to these practices, as appropriate. 1.4 In this test method, metric units are used for all applications except linear measure. In that case, inches are used and metric units follow in parentheses. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Performance of this procedure requires the knowledge of regulations pertaining to the protection of human subjects (see 21 CFR, Ch. I, Parts 50 and 56 ). |
||