Standard Test Method for Determining Oxidation Induction Time of Hydrocarbons by Differential Scanning Calorimetry
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie Oxidácia Indukčné doba uhľovodíkov diferenčnej skenovacej kalorimetrie
NORMA vydaná dňa 10.3.2003
Označenie normy: ASTM E1858-03
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.3.2003
Kód tovaru: NS-43339
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
differential scanning calorimetry, hydrocarbons, isothermal temperature, oxidation, oxidation induction time, oxidative stability, pressure differential scanning calorimetry
| Significance and Use | ||||||||||||||||||||||||
|
Oxidative induction time is a relative measure of the degree of oxidative stability of the material evaluated at the isothermal temperature of the test. The presence, quantity or effectiveness of antioxidants may be determined by this method. The OIT values thus obtained may be compared from one hydrocarbon to another or to a reference material to obtain relative oxidative stability information. Typical uses include the oxidative stability of edible oils and fats (oxidative rancidity), lubricants, greases, and polyolefins. |
||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||
|
1.1 This test method describes the determination of the oxidative properties of hydrocarbons by differential scanning calorimetry or pressure differential scanning calorimetry and is applicable to hydrocarbons that oxidize exothermically in their analyzed form. 1.2 Computer or electronic-based instruments, techniques or data treatment equivalent to this test method may also be used. Note 1—Since all electronic data treatments are not equivalent, the user shall verify equivalency to this method. 1.3 Test Method A— A differential scanning calorimeter (DSC) is used at ambient pressure, for example, about 100 kPa of oxygen. 1.4 Test Method B—A pressure DSC (PDSC) is used at high pressure, for example, 3.5 MPa (500 psig) oxygen. 1.5 SI values are the standard. 1.6 This test method is related to ISO 11357-6 but is different in technical content. This test method is related to CEC L-85-T but includes additional experimental conditions. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Note 6 and Note 14. |
||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-01-11 (Počet položiek: 2 254 176)
© Copyright 2026 NORMSERVIS s.r.o.