Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities (Includes all amendments and changes 2/25/2019).
NORMA vydaná dňa 1.7.2017
Označenie normy: ASTM E1746-17a
Dátum vydania normy: 1.7.2017
Kód tovaru: NS-688972
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
analysis, carbon dioxide, carbon monoxide, gas chromatography, hydrogen, inert gases, liquid chlorine, nitrogen, oxygen,, ICS Number Code 71.060.10 (Chemical elements)
Significance and Use | ||||
4.1 It is very difficult to exclude sample contamination by ambient air during the process of sampling. The levels of atmospheric contamination caused by poor sampling methods are often equal to or larger than the levels of the gaseous impurities present in the chlorine. This results in markedly elevated levels of detected impurities. As specifications become tighter, it becomes more important to measure the gaseous impurity levels in liquid chlorine correctly. 4.2 Additional problems are experienced in the sampling of liquefied gases for the gaseous impurities. The gaseous impurities reach an equilibrium between the liquid phase and vapor phase in a sample bomb. The quantity of gases measured in any particular sample containing both liquid and vapor will be a function of the amount of vapor space in the sample bomb. This test method avoids the presence of liquid in the sample bomb. |
||||
1. Scope | ||||
1.1 This test method covers sampling and analysis of liquid chlorine for the determination of oxygen (200 to 400 μg/g), nitrogen (400 to 800 μg/g), and carbon dioxide (800 to 1000 ppm) content at levels normally seen in liquid chlorine. Hydrogen and carbon monoxide concentrations in liquid chlorine are typically at or below the detection limit of this test method. Note 1: The minimum detection limit of hydrogen using a 1
cm3 gas sample and argon carrier gas is 100 to 200
μg/g.1.2 The values stated in SI units are to
be regarded as standard. No other units of measurement are included
in this standard.
1.3 Review the current Safety Data Sheets (SDS) for detailed information concerning toxicity, first aid procedures, and safety precautions. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 7. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||