Standard Guide for Use of Lighting in Laboratory Testing
NORMA vydaná dňa 1.8.2022
Označenie normy: ASTM E1733-22
Dátum vydania normy: 1.8.2022
Kód tovaru: NS-1083929
Počet strán: 15
Približná hmotnosť: 45 g (0.10 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
action spectrum, artificial lighting, simulated solar radiation, spectral distribution, sunlight, ultraviolet radiation, visible light ,, ICS Number Code 91.160.10 (Interior lighting)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||
5.1?The information in this guide is designed to allow investigators conducting research or tests of environmental relevance to select appropriate light sources. 5.2?Investigators will be able to make reasonable selections of light sources based on cost, the requirements of the test organisms, and the properties of the test chemicals. 5.3?These methods have major significance for the comparison of results between laboratories. Investigators at different sites will be able to select similar light sources. This will provide standardization of a factor that can have major impact on the effects of hazardous chemicals. |
||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||
1.1?The use of artificial lighting is often required to study the responses of living organisms to contaminants in a controlled manner. Even if the test organism does not require light, the investigator will generally need light to manipulate the samples, and the test might be conducted under the ambient light of the laboratory. One will need to consider not only whether the particular test organism requires light for growth, but also whether the environmental compartment relevant to the test is exposed to light and, if so, what the attributes of light are in that compartment. The light could affect growth of the organism or toxicity of a contaminant, or both. For instance, it has been shown that the toxicity of some organic pollutants is enhanced dramatically by the ultraviolet (UV) radiation present in sunlight 1.2?It is possible to simulate sunlight with respect to the visible:UV ratio with relatively inexpensive equipment. This guide contains information on the types of artificial light sources that are commonly used in the laboratory, compositions of light sources that mimic the biologically relevant spectral range of sunlight, quantification of irradiance levels of the light sources, determination of spectral outputs of the light sources, transmittance properties of materials used for laboratory containers, calculation of biologically effective radiation, and considerations that should go into designing a relevant light source for a given test. 1.3?Special needs or circumstances will dictate how a given light source is constructed. This is based on the requirements of the test and the environmental compartment to which it is targeted. Using appropriate conditions is most important for any experiment, and it is desirable to standardize these conditions among laboratories. In extreme cases, tests using unusual lighting conditions might render a data set incomparable to other tests. 1.4?The lighting conditions described herein are applicable to tests with most organisms and using most chemicals. With appropriate modifications, these light sources can be used under most laboratory conditions with many types of laboratory vessels. 1.5?The attributes of the light source used in a given study should list the types of lamps used, any screening materials, the light level as an energy fluence rate (in W m?2 ) or photon fluence rate (in ?mol m?2 s?1 ), and the transmission properties of the vessels used to hold the test organism(s). If it is relevant to the outcome of a test, the spectral quality of the light source should be measured with a spectroradiometer and the emission spectrum provided graphically for reference. 1.6?The sections of this guide are arranged as follows:
1.7?The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.8?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.9?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||
|