Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems by Uniform Static Air Pressure Difference
NORMA vydaná dňa 1.11.2018
Označenie normy: ASTM E1646-95(2018)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.11.2018
Kód tovaru: NS-904476
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
air, air pressure, leakage, mastic, metal, panel, ponding, pressure, rain, roof, roof panel, side lap, side seam, static, structural, thermal expansion, water, water leakage, water penetration, water-spray ,, ICS Number Code 91.060.20 (Roofs)
Significance and Use | ||||||||||
5.1 This test method is a standard procedure for determining the resistance to water penetration under uniform positive static air pressure differences, and simulates wind driven rain imposed on sidelaps and rain that is free to drain while building a water head as it flows. The slope of the roof is significant. These factors shall be fully considered prior to specifying the test pressure difference. Note 1: In applying the results of tests by this method, note
that the performance of a roof or its components, or both, may be a
function of proper installation and adjustment. In service, the
performance also depends on the rigidity of supporting
construction, roof slope, and on the resistance of components to
deterioration by various causes: corrosive atmosphere, aging, ice,
vibration, thermal expansion and contraction, etc. It is difficult
to simulate the identical complex wetting conditions that can be
encountered in service, including large wind-blown water drops,
increasing water drop impact pressures with increasing wind
velocity, and lateral or upward moving air and water. Some designs
are more sensitive than others to this upward moving
water.
Note 2: This is a test procedure. It is the responsibility of
the specifying agency to determine the specimen construction, size,
and test pressures after considering the method’s guidelines.
Practical considerations suggest that every combination of panel
thickness, span, and design load need not be tested in order to
substantiate product performance.
Note 3: This test method shall not, by itself, be relied upon
to form conclusions about overall water penetration through metal
roofs. A roof contains many details. Although prescribed
modifications are outside the scope of this test method, an
experienced testing engineer is able to use the principles
presented in this test method and generate significant data by
isolating specific details and measuring leakage.
|
||||||||||
1. Scope | ||||||||||
1.1 This test method covers the determination of the resistance of exterior metal roof panel systems to water penetration when water is applied to the outdoor face simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face, that is, positive pressure. This test method is a specialized adaption of Test Method E331. 1.2 This test method is applicable to any roof area and is intended to measure only the water penetration associated with the field of roof including panel side laps and structural connections. It does not include leakage at openings or perimeter or any other details. 1.3 This test method is limited to specimens in which the side seams and attachments are clearly visible and in which the source of leakage is readily determined. Composite systems in which the source cannot be readily determined are outside the scope of this test method. 1.4 The proper use of this test method requires a knowledge of the principles of pressure and flow measurement. 1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.6 The text of this test method references notes and footnotes excluding tables and figures, which provide explanatory material. These notes and footnotes shall not be considered as requirements of the test method. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||
2. Referenced Documents | ||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-22 (Počet položiek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.