Standard Practice for Use of Calorimetric Dosimetry Systems for Electron Beam Dose Measurements and Dosimeter Calibrations (Withdrawn 2002) (Includes all amendments And changes 2/18/2021).
Automaticky preložený názov:
Štandardná prax pre využívanie kalorimetrického dozimetrie systémov pre elektrónový lúč Dávka merania a dozimeter Kalibrácia ( Withdrawn 2002 )
NORMA vydaná dňa 10.6.1999
Označenie normy: ASTM E1631-96e1
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.6.1999
Kód tovaru: NS-42442
Počet strán: 9
Približná hmotnosť: 27 g (0.06 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Absorbed radiation dose, Calibration-nuclear analysis instrumentation, Calorimeter, Dosimetry, Electron beam, Graphite, Ionizing radiation, Irradiance/irradiation, Polystyrene (PS), Radiation exposure-nuclear materials/applications, Threshold detectors-4 to 12 MeV, Water, ICS Number Code 17.240 (Radiation measurements)
1. Scope | ||||||||||
1.1 This practice covers the preparation and use of semi-adiabatic calorimeters for measurement of absorbed dose in graphite, water, or polystyrene when irradiated with electrons. The calorimeters are either transported by a conveyor past a scanned electron beam or are stationary in a broadened beam. It also covers the use of these calorimeters to calibrate dosimeter systems in electron beams intended for radiation processing applications. 1.2 This practice applies to electron beams in the energy range from 4 to 12 MeV. 1.3 The absorbed dose range depends on the absorbing material and the irradiation and measurement conditions. Minimum dose is approximately 100 Gy and maximum dose is approximately 50 kGy. 1.4 The averaged absorbed dose rate range shall generally be greater than 10 Gy[dot]s -1 , but depends on the same conditions as above. 1.5 The temperature range for use of these calorimeters depends on the thermal resistance of the materials and on the calibration range of the temperature sensor. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-07-17 (Počet položiek: 2 336 011)
© Copyright 2024 NORMSERVIS s.r.o.