Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Evaluating the Performance of Antimicrobials in or on Polymeric Solids Against Staining by Streptomyce species (A Pink Stain Organism)
Automaticky preložený názov:
Štandardná skúšobná metóda pre hodnotenie výkonnosti antimikrobiálnych látok alebo polymérnych pevných látok proti znečisteniu podľa Streptomyce druhov ( Pink Stain organizmu )
NORMA vydaná dňa 15.2.2015
Označenie normy: ASTM E1428-15
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.2.2015
Kód tovaru: NS-590493
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
antimicrobial efficacy, pink stain, plastics, polymeric solids, Streptomyces species,, ICS Number Code 07.100.99 (Other standards related to microbiology), 83.080.01 (Plastics in general)
Significance and Use | ||||||
5.1 Methods such as D3273 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber and D3274 Standard Test Method for Evaluating the Degree of Surface Disfigurement of Paint Films by Fungal or Algal Growth or Soil or Dirt Accumulation provide means for assessing mold and algal staining on paints. 5.2 This test method provides a technique for evaluating antimicrobials in or on polymeric solids against staining by 5.3 Conditioning of the specimens, such as exposure to leaching, weathering, and heat treatment, may have significant effects on performance of antimicrobials against staining. Determination of these effects is not included in this test method. |
||||||
1. Scope | ||||||
1.1 This test method is intended to assess susceptibility of vinyl and other solid polyer products as well as products that may directly contact vinyl to pink-staining by the actinomycete bacteria Streptomyces species. 1.2 This test method is not suitable for evaluating dark-pigmented test samples. 1.3 A knowledge of microbiological techniques is recommended for these procedures. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-12-22 (Počet položiek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.