Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Liquid Penetrant Testing
Automaticky preložený názov:
Štandardné praktiky pre kapilárne testovanie
NORMA vydaná dňa 1.6.2013
Označenie normy: ASTM E1417/E1417M-13
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.6.2013
Kód tovaru: NS-41696
Počet strán: 11
Približná hmotnosť: 33 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
dye liquid penetrant examination, dye penetrant examination, fluorescent liquid penetrant examination, fluorescent penetrant examination, liquid penetrant examination, liquid penetrant testing, nondestructive, nondestructive evaluation, nondestructive examination, nondestructive testing, penetrant examination, penetrant testing, ICS Number Code 19.040 (Environmental testing)
Significance and Use | ||||||||||||||||||||||||||||
4.1 This practice establishes the basic parameters for controlling the application of the liquid penetrant method. This practice is written so it can be specified on the engineering drawing, specification, or contract. It is not a detailed how-to procedure to be used by the inspector and, therefore, must be supplemented by a detailed procedure that conforms to the requirements of this practice. Specification E165 contains information to help develop detailed requirements. |
||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||
1.1 This practice establishes the minimum requirements for conducting liquid penetrant examination of nonporous metal, and nonmetal components. 1.2 The penetrant examination
processes described in this practice are applicable to in-process,
final, and maintenance (in-service) examinations. These processes
are applicable for the detection of discontinuities, such as lack
of fusion, corrosion, cracks, laps, cold shuts, and porosity, that
are open or connected to the surface of the component under
examination.
1.3 Caution must be exercised in the usage of elevated temperature with components manufactured from thermoplastic materials. Also, some cleaners, penetrants, and developers can have a deleterious effect on nonmetallic materials such as plastics. Prior to examination, tests should be conducted to ensure that none of the cleaning or examination materials are harmful to the components to be examined. 1.4 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.5 All areas of this practice may be open to agreement between the cognizant engineering organization and the supplier, or specific direction from the cognizant engineering organization. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|
Historická
15.12.2012
Historická
1.6.2013
Historická
1.6.2009
Historická
1.11.2012
Historická
1.6.2013
Historická
1.12.2009
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.