Standard Guide for Conduct of Micronucleus Assays in Mammalian Bone Marrow Erythrocytes (Withdrawn 2015)
Automaticky preložený názov:
Štandardné Príručka pre správanie mikronukleovom Testy v bunkách kostnej drene cicavcov erytrocytov ( Withdrawn 2015 )
NORMA vydaná dňa 1.8.2008
Označenie normy: ASTM E1263-97(2008)
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.8.2008
Kód tovaru: NS-41064
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Assay, Bone marrow nucleus assay, Chromosomal/genetic effects, Data analysis--environmental, Environmental control/fate, Environmental sampling/testing, Genetic examination, Mammalian in vivo bone marrow nucleus assay, Micronucleus assay, Statistical methods, Test animals, ICS Number Code 11.220 (Veterinary medicine)
Significance and Use |
This guide provides guidelines for the selection of animal species, dosage and sampling conditions, sampling and scoring methods, statistical design, and analysis of genotoxicity assays in which the endpoint measured is the frequency of micronucleated erythrocytes in mammalian bone marrow. |
1. Scope |
1.1 This guide provides recommended guidelines for performing the mammalian in vivo bone marrow micronucleus assay. Under appropriate test conditions, measurement of the frequency of newly formed micronucleated erythrocytes in bone marrow provides a convenient index of chromosomal damage in nucleated erythrocyte precursor cells. The rationale for the occurrence of micronuclei in conjunction with chromosomal damage has been described previously (1). This guide describes conditions under which the frequency of micronucleated erythrocytes in mammalian bone marrow is an appropriate measure of in vivo chromosomal damage, and provides guidelines for the design and technical execution of assays employing this endpoint. 1.2 The following guidelines for mammalian bone marrow erythrocyte micronucleus assays have been published by organizations concerned with the evaluation of genotoxicity test data. These references should be consulted for recommendations on details not covered in depth by this guide and for requirements of specific organizations or government agencies (2-6). 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |