Standard Test Method for Thermal Conductivity of Solids by Means of the Guarded-Comparative-Longitudinal Heat Flow Technique
Automaticky preložený názov:
Štandardná skúšobná metóda pre tepelnej vodivosti pevných látok pomocou stráženého - porovnávacieho - Pozdĺžny toku tepla Technika
NORMA vydaná dňa 10.3.1999
Označenie normy: ASTM E1225-99
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.3.1999
Kód tovaru: NS-40927
Počet strán: 8
Približná hmotnosť: 24 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Alloys, Austenitic steel, Carbon, Ceramic materials, Comparison techniques, Copper, Copper alloy, Glass, Graphite, Guarded heat flow technique, Heat flow, Heating tests-chemicals/materials, Insulation, Iron, Metals and metallic materials, Meter bar materials, Polymers, Refractories (general), Sensors, Silica content, Solid phase materials, Thermal conductivity, Thermal insulating materials, Thermal transmission properties, Tungsten
| 1. Scope | ||
|
1.1 This test method describes a steady state technique for the determination of the thermal conductivity, [lambda], of homogeneous-opaque solids (see Notes 1 and 2). This test method is for materials with effective conductivities in the approximate range 0.2 ∧ [lambda] ∧ 200 W/ [dot]K over the approximate temperature range between 90 and 1300 K. It can be used outside these ranges with decreased accuracy. Note 1-For purposes of this technique, a system is homogeneous if the apparent thermal conductivity of the specimen, [lambda] , does not vary with changes of thickness or cross-sectional area by more than +5%. For composites or heterogeneous systems consisting of slabs or plates bonded together, the specimen should be more than 20 units wide and 20 units thick, respectively, where a unit is the thickness of the thickest slab or plate, so that diameter or length changes of one-half unit will affect the apparent [lambda] by less than +5%. For systems that are non-opaque or partially transparent in the infrared, the combined error due to inhomogeneity and photon transmission should be less than +5%. Measurements on highly transparent solids must be accompanied with infrared absorption coefficient information or the results must be reported as apparent [lambda] . Note 2-This test method may also be used to evaluate the thermal conductance/resistance of materials in contact.1.2 This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
| 2. Referenced Documents | ||
|