Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Practice for Determination of the Specimen Area Contributing to the Detected Signal in Auger Electron Spectrometers and Some X-Ray Photoelectron Spectrometers
Automaticky preložený názov:
Štandardná prax pre určovanie plochy vzoru prispievajúcich k Zistené signálu v Auger elektrónové spektrometre a niektoré X - Ray Photoelectron spektrometre
NORMA vydaná dňa 10.4.2000
Označenie normy: ASTM E1217-00
Poznámka: NEPLATNÁ
Dátum vydania normy: 10.4.2000
Kód tovaru: NS-40895
Počet strán: 7
Približná hmotnosť: 21 g (0.05 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Absorbed current, Computer programs, Current measurement, Deflection, Detectors, Line scan, Oscilloscope, Raster scan, Scanning, Signal detection, Specimen area, Spectrometry, Spectroscopy-auger electron (AES), Spectroscopy-x-ray photoelectron, Surface analysis-spectrochemical analysis, Topography, Voltage, Waveform, specimen area contributing to detected signal in, photoelectron/auger-electron spectroscopy, practice, ICS Number Code 71.040.50 (Physicochemical methods of analysis)
| 1. Scope | ||||||
|
1.1 This practice describes methods for determining the specimen area contributing to the detected signal in X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES) when this area is defined by the electron collection lens/aperture system. It is recommended as a useful means of determining the observed specimen area for different conditions of spectrometer operation, verifying adequate specimen alignment, and characterizing the imaging properties of the electron energy analyzer. 1.2 This practice is intended only for spectrometers in which the specimen area excited by X-ray or electron beams is or can be made larger than the specimen area viewed by the analyzer. It is assumed that, under normal conditions of operation, the specimen is excited by a beam of X rays or electrons that can be considered to have a uniform intensity over the specimen area viewed by the analyzer, and the specimen is homogeneous and uniform over the observed area. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
| 2. Referenced Documents | ||||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2026-04-22 (Počet položiek: 2 274 512)
© Copyright 2026 NORMSERVIS s.r.o.