Standard Test Method for Estimating Acute Oral Toxicity in Rats
NORMA vydaná dňa 1.2.2019
Označenie normy: ASTM E1163-10(2019)
Dátum vydania normy: 1.2.2019
Kód tovaru: NS-936802
Počet strán: 3
Približná hmotnosť: 9 g (0.02 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
chemicals, LD50, oral toxicity, pesticides, rats,, ICS Number Code 65.100.99 (Other pesticides and agrochemicals)
Significance and Use | ||||
5.1 This test method is of principal value in minimizing the number of animals required to estimate the acute oral toxicity (LD50). It also incorporates measures of variance (95 % CI) and a slope from which to make relative toxicity comparisons. 5.2 This test method is inappropriate for materials typically producing death two or more days after administration of the test compound unless the observation time between dosages is increased. This test method can be successfully applied, however, for materials producing only an occasional death two or more days after administration. 5.3 The LD50 is valuable as a measure of the relative acute toxicity of a material and can be used to make an estimate of potential hazard to humans when pesticides, other chemicals, or mixtures are ingested. 5.4 This test method allows for observation of signs of toxicity in addition to mortality. This information can be useful in planning additional toxicity testing. |
||||
1. Scope | ||||
1.1 This test method determines the lethality (LD50 value, slope and 95 % confidence interval (CI)) and signs of acute toxicity from a material using a limited number of rats. The technique used in this test method is referred to as the “Stagewise, Adaptive Dose Method.”2 This test method is an alternative to the classical LD50 test and is applicable to both liquids and solids. 1.2 This test method is not recommended for test materials which typically produce deaths beyond two days postdosing. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||
2. Referenced Documents | ||||
|
Chcete mať istotu, že používate len platné technické normy?
Ponúkame Vám riešenie, ktoré Vám zaistí mesačný prehľad o aktuálnosti noriem, ktoré používate.
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.