Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Dioctyl Sulfosuccinate in Sea Water by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie dioktylsulfosukcinát v morskej vode sa kvapalinová chromatografia / Tandemový hmotnostnej spektrometrie (LC / MS / MS)
NORMA vydaná dňa 1.5.2011
Označenie normy: ASTM D7730-11
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.5.2011
Kód tovaru: NS-39031
Počet strán: 11
Približná hmotnosť: 33 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
Dioctyl Sulfosuccinate , Liquid Chromatography, Mass Spectrometry, Water, ICS Number Code 71.060.50 (Salts)
Significance and Use | ||||||
DOSS is an anionic detergent that is approved by the Food and Drug Administration and is used widely as a laxative, emulsifying, solubilizing and dispersing agent, and is used in the cosmetic industry. DOSS may also be used as a dispersing agent to treat oil. DOSS may be released into the environment at levels that may be harmful to aquatic life. The US EPA aquatic life benchmark for DOSS is 40 ppb. This method has been investigated for use with reagent and sea water. |
||||||
1. Scope | ||||||
1.1 This procedure covers the determination of dioctyl sulfosuccinate (DOSS) in sea water by direct injection using liquid chromatography (LC) and detection with tandem mass spectrometry (MS/MS). This analyte is qualitatively and quantitatively determined by this method. This method adheres to selected reaction monitoring (SRM) mass spectrometry. 1.2 The Detection Verification Level (DVL) and Reporting Range for DOSS are listed in Table 1. 1.2.1 The DVL is required to be at a concentration at least 3 times below the Reporting Limit (RL) and have a signal/noise ratio greater than 3:1. Fig. 1 and Fig. 2 display the signal/noise ratio of the selected reaction monitoring (SRM) transition. 1.2.2 The reporting limit is the concentration of the Level 1 calibration standard as shown in Table 5 for DOSS, taking into account the 50% sample preparation dilution factor. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 Detection Verification Level and Reporting Range
|
||||||
2. Referenced Documents | ||||||
|
Historická
1.1.2014
Historická
15.3.2011
Historická
1.4.2012
Historická
1.10.2009
Historická
15.12.2013
Historická
1.4.2008
Chcete mať istotu o platnosti využívaných predpisov?
Ponúkame Vám riešenie, aby ste mohli používať stále platné (aktuálne) legislatívne predpisy
Chcete vedieť viac informácií ? Pozrite sa na túto stránku.
Posledná aktualizácia: 2025-05-05 (Počet položiek: 2 198 283)
© Copyright 2025 NORMSERVIS s.r.o.