Potrebujeme váš súhlas na využitie jednotlivých dát, aby sa vám okrem iného mohli ukazovať informácie týkajúce sa vašich záujmov. Súhlas udelíte kliknutím na tlačidlo „OK“.
Standard Test Method for Determination of Static Dissipater Additives (SDA) in Aviation Turbine Fuel and Middle Distillate Fuels´High Performance Liquid Chromatograph (HPLC) Method
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie statické Dissipater prídavné látky (SDA) v letecké turbínové palív a stredných destilátov Fuels'High kvapalinový chromatograf (HPLC) Metóda
NORMA vydaná dňa 15.2.2010
Označenie normy: ASTM D7524-10
Poznámka: NEPLATNÁ
Dátum vydania normy: 15.2.2010
Kód tovaru: NS-38665
Počet strán: 6
Približná hmotnosť: 18 g (0.04 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
aviation turbine fuel, high performance liquid chromatography, middle distillate, solid phase extraction, static dissipater additive, ICS Number Code 75.160.20 (Liquid fuels)
Significance and Use | ||||||
This test method will allow the determination of static dissipater additive in jet and middle distillate. These additives reduce the hazardous effects of static electricity generated by transfer and movement of jet and middle distillate fuels. |
||||||
1. Scope | ||||||
1.1 This test method covers the determination of static dissipater additive (SDA) content of aviation turbine fuel and middle distillate fuels. 1.2 The precision of this test method has been established for aviation turbine fuel over the concentration range of 1 to 12 mg/L. Higher concentrations can be determined by dilution, but the precision of the test method will not apply. Note 1—The SDA used to develop this test method was STADIS 450 for aviation fuels and STADIS 450 and 425 for middle distillates. 1.3 The test method includes a procedure to concentrate the sulfonic acid component in the SDA prior to analysis. 1.4 The test method only applies to SDAs that contain alkyl substituted sulfonic acid. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Posledná aktualizácia: 2024-11-04 (Počet položiek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.