Standard Test Method for Determination of Nonylphenol, p-tert-Octylphenol, Nonylphenol Monoethoxylate and Nonylphenol Diethoxylate in Environmental Waters by Liquid Chromatography/Tandem Mass Spectrometry
Automaticky preložený názov:
Štandardná skúšobná metóda pre stanovenie nonylfenol, p-terc-oktylfenol nonylfenolu Monoethoxylate a nonylfenol Diethoxylate vo vodách v oblasti životného prostredia sa kvapalinová chromatografia / Tandem hmotnostnej spektrometrie
NORMA vydaná dňa 1.3.2009
Označenie normy: ASTM D7485-09
Poznámka: NEPLATNÁ
Dátum vydania normy: 1.3.2009
Kód tovaru: NS-38583
Počet strán: 10
Približná hmotnosť: 30 g (0.07 libier)
Krajina: Americká technická norma
Kategória: Technické normy ASTM
Keywords:
diethoxylate, liquid chromatography, monoethoxylate, nonylphenol, octylphenol, solid phase extraction, tandem mass spectrometry, water, ICS Number Code 13.060.50 (Examination of water for chemical substances)
Significance and Use | ||||||||||||||||
NP and OP have been shown to have toxic effects in aquatic organisms. The source of NP and OP is prominently from the use of common commercial surfactants. The most widely used surfactant is nonylphenol ethoxylate (NPEO) which has an average ethoxylate chain length of nine. The ethoxylate chain is readily biodegraded to form NP1EO, NP2EO, nonylphenol carboxylate (NPEC) and, under anaerobic conditions, NP. NP will also biodegrade, but may be released into environmental waters directly at trace levels. This method has been investigated and is applicable for environmental waters, including seawater. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This test method covers the determination of nonylphenol (NP), nonylphenol ethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO), and octylphenol (OP), extracted from water utilizing solid phase extraction (SPE), separated using liquid chromatography (LC) and detected with tandem mass spectrometry (MS/MS). These compounds are qualitatively and quantitatively determined by this method. This method adheres to single reaction monitoring (SRM) mass spectrometry. 1.2 The method detection limit (MDL) and reporting limit (RL) for NP, NP1EO, NP2EO, and OP are listed in Table 1. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. TABLE 1 MDL and Reporting Limits
A MDL Determined Following The Code of Federal Regulations, 40 CFR Part 136, Appendix B. B Lowest Point of the Reporting Range is Calculated from the LV 1 Concentration Calibration Standard in Table 4. |
||||||||||||||||